Calibration of the Machine

Programming

Program Cycle 00

Total working hours : 0

level : 0.0 “ Enter to zero

Spin

XXX rpm

Reference x.xx

Calibration of the Machine

The _x__PV should reflect the size selected in earlier steps.

Turn key to Program Mode.

Press “Auxiliary”, “3”, “1”.

The total hours the machine was running will be displayed.

Press “Advance” and screen will show total cycles. Press “Advance” to calibrate the water level sensor.

If the value is not zero, press “Enter” and the value will change to zero.

Press “Advance” to calibrate the motor.

The board will lock the door and let the motor spin at approximately 500 rpm (Firmware version 1.12 or higher). The rpm will increase on the display. If the machine reached approximately 500 rpm, the display will show a reference value.

After the reference value is shown, the machine will coast down to stop. When the machine stands still, the board will unlock the door.