Programming

Programming

Setup of the Machine

RUN

PROGRAM

Turn key from Run to Program

 

Program Cycle 00

To go to the main setup of the machine, press “Auxiliary”, “2”, “9”.

System Program

_X18PV

System Program

_X25PV

Units: English

Units: Metric

Drain 1 : Valve

Drain 2 : None

Drain 1 : Pump

Drain 2 : None

To change the machine type, press the “Advance” button.

The following types are possible:

_X18PV _X40PV _X135PV

_X25PV _X55PV _X165PV

_X33PV _X75PV _X200PV

Press the “Advance” button until the right type of machine is selected. Press the “Enter” button.

Select the desired units.

NOTE: English means level in inch and temperature in °F.

Metric means level in cm and temperature in °C.

Press the “Advance” button to change the units.

Press the “Enter” button.

Select the type of drain valve.

Press “1” to change drain 1 to pump or valve. Press “2” to change drain 2 to pump, valve or none.