Alliance Laundry Systems 9001889R7 manual Inverter Drive Error Codes, Operation, Name, Check point

Models: 9001889R7

1 62
Download 62 pages 8.61 Kb
Page 58
Image 58
Inverter Drive Error Codes

Inverter Drive Error Codes

Operation

Name

Description and NOTES

Check point

Corrective action

Panel

Indication

 

 

 

 

 

 

Overcurrent

When the inverter output current reaches

Check the motor

Repair the wiring.

 

shut-off during

or exceeds approximately 200% of the

cable insulation and

 

 

acceleration

rated current during acceleration, the

connection for output

 

 

 

protective circuit is activated to stop the

short-circuit/ground

 

 

 

inverter output.

fault.

 

 

 

 

 

 

 

 

 

Overcurrent

When the inverter output current reaches

Check the motor

Repair the wiring.

 

shut-off during

or exceeds approximately 200% of the

cable insulation and

 

 

constant speed

rated current during constant speed, the

connection for output

 

 

 

protective circuit is activated to stop the

short-circuit/ground

 

 

 

inverter output.

fault.

 

 

 

 

 

 

 

 

Overcurrent

When the inverter output current reaches

Check for sudden

Contact Alliance

 

shut-off during

or exceeds approximately 200% of the

speed reduction.

Laundry Systems’

 

deceleration

rated current during deceleration (other

Check the motor

Customer Service

 

 

than acceleration or constant speed), the

cable insulation and

department.

 

 

protective circuit is activated to stop the

connection for

Repair the wiring.

 

 

inverter output.

output short-circuit/

 

 

 

 

ground fault.

 

 

Regenerative

If regenerative energy causes the

Check to make sure

Load the machine

 

overvoltage

inverter’s internal main circuit DC voltage

the machine is loaded

properly to distribute

 

shut-off during

to reach or exceed the specified value, the

properly and that the

the load evenly.

 

acceleration

protective circuit is activated to stop the

load is balanced.

 

 

 

inverter output. It may also be activated

 

 

 

 

 

by a surge voltage generated in the power

 

 

 

 

 

supply system.

 

 

 

 

 

 

 

 

 

Regenerative

If regenerative energy causes the

Check to make sure

Load the machine

 

overvoltage

inverter’s internal main circuit DC voltage

the machine is loaded

properly to distribute

 

shut-off during

to reach or exceed the specified value, the

properly and that the

the load evenly.

 

constant speed

protective circuit is activated to stop the

load is balanced.

 

 

 

inverter output. It may also be activated

 

 

 

 

 

by a surge voltage generated in the power

 

 

 

 

 

supply system.

 

 

 

 

 

 

 

 

 

Regenerative

If regenerative energy causes the

Check to make sure

Load the machine

 

overvoltage

inverter’s internal main circuit DC voltage

the machine is loaded

properly to distribute

 

shut-off during

to reach or exceed the specifed value, the

properly and that the

the load evenly.

 

deceleration or

protective circuit is activated to stop the

load is balanced.

 

 

stop

inverter output. It may also be activated

 

 

 

 

 

by a surge voltage generated in the power

 

 

 

 

 

supply system.

 

 

 

 

 

 

 

 

 

Motor overload

The electronic overcurrent protection in

Verify that the AC

Contact Alliance

 

shut-off

the inverter detects motor overheat due to

drive’s parameters are

Laundry Systems’

 

(electronic

overload or reduced cooling capability

correct.

Customer Service

 

overcurrent

due to overload or reduced cooling

 

 

department.

 

protection)

capability during constant-speed operation

 

 

 

 

 

to stop the inverter output. When a multi-

 

 

 

 

 

pole motor or two or more motors are run,

 

 

 

 

 

provide a thermal relay in the output side

 

 

 

 

 

of the inverter.

 

 

 

 

 

 

 

 

 

56

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9001889

Page 58
Image 58
Alliance Laundry Systems 9001889R7 manual Inverter Drive Error Codes, Operation, Name, Description and NOTES, Check point