Error Messages

PowerTools Pro will pop-up an error message box to alert you to any errors it encounters. These message boxes will describe the error and offer a possible solution.

The table below list the of common problems you might encounter when working with PowerTools Pro software along with the error message displayed, the most likely cause and solution.

Problem/Message

Cause

Solution

Time-out while waiting for device response.

 

Check the serial connection to the device and

The attempted operation has been cancelled.

Loss of serial communications.

try operation again.

(see fault: No device selected)

 

 

 

 

 

 

The attached device(s) do not have valid

Attempting to broadcast to drive without

Program each drive individually.

revisions, or do not have matching revisions.

matching firmware revisions.

 

 

 

 

Unable to communicate with device [Address

The device that you are attempting to

Check all connections and verify that you are

x]

communicate with is no longer available.

using the correct baud rate then try again.

 

 

 

The specified drive type (name) does not

The drive type you selected in the “Drive

Change the drive type selected in the “Drive

match the actual drive type (name). Please

Type” list box does not match the drive you

Type” list box to match the drive you are

make necessary corrections.

are downloading to.

downloading to.

 

 

 

Non-Control-Techniques device attached

This error is caused When you attempting to

Disconnect the device(s) that has been

(address). When trying to program more than

perform an upload or download to multiple

specified and try the operation again or

one drive, only EMC drives of the same type

drives and one or more of the drives are not

program each device individually.

can be attached to the network.

the same type.

 

 

 

 

You have changed a parameter which will

 

 

not take effect until the drive has been

 

 

rebooted. Before you reboot the drive, you

See message.

Yes/No.

will need to save your setup to NVM. Do you

 

 

wish to save your setup to drive NVM now?

 

 

 

 

 

(Operation Name) The attempted operation

Communication error.

Retry operation. Check connection to drive.

has been cancelled.

 

 

 

 

 

Invalid entry. The entry exceeds the precision

 

Enter a value within the range of that field.

allowed by this field. The finest resolution

Entered a value out of range.

The status bar displays information on the

this field accepts is (value).

 

currently selected object or action.

 

 

 

The device was disconnected during the

Connection to the device was lost (a time-out

Check the connection to the device and try

upload. The upload was not complete.

occurred).

again.

 

 

 

The device was disconnected during the

Connection to the device was lost (a time-out

Check the connection to the device and try

download. The download was not complete.

occurred).

again.

 

 

 

 

 

Check all connections.

No device selected.

The device you are attempting to

Verify the baudrate.

Verify that the “Maximum Node Address”

communicate with is not responding.

 

value is at least the value of the address of the

 

 

 

 

drive connected.

 

 

 

118