Operational Overview

Index6

Index5 Index5

Index6

Dwell

End of Index

Motion

End of Index

End of Index

Count

Run Next

Index

Run Next Index

Input Function

Turned On

Figure 70: Example 3 – Index5 is chained to Index6 using the Wait for Run Next Index input function.

How Alternate Mode Works

In addition to Jog, Index, and Home functions, the EP-I drive provides three basic modes of operation in Alternate Mode: Analog Velocity, Analog Torque, and Pulse Mode.

When in Alternate Mode the drive will ignore all Index, Home, or Jog initiate requests. If the drive is indexing, homing, or jogging when alternate mode is turned on, the drive will initiate a stop command and use the stop decel to ramp down to zero, then it will switch into alternate mode.

Figure 71: Alternate Mode Screen - Pulse Mode

69

Page 81
Image 81
Emerson P/N 400518-02 manual How Alternate Mode Works, Alternate Mode Screen Pulse Mode