Epsilon EP-I Indexing Drive and FM-2 Indexing Module Reference Manual

functions. The table below shows this concept. The status of the four Index Select Input functions are combined together to form a 4 bit binary number.

Index

Index

Index

Index

Selected

Select #0

Select #1

Select #2

Select #3

Index

(value = 1)

(value = 2)

(value = 4)

(value = 8)

 

Off

Off

Off

Off

0

 

 

 

 

 

On

Off

Off

Off

1

 

 

 

 

 

Off

On

Off

Off

2

 

 

 

 

 

On

On

Off

Off

3

 

 

 

 

 

Off

Off

On

Off

4

 

 

 

 

 

On

Off

On

Off

5

 

 

 

 

 

Off

On

On

Off

6

 

 

 

 

 

On

On

On

Off

7

 

 

 

 

 

Off

Off

Off

On

8

 

 

 

 

 

On

Off

Off

On

9

 

 

 

 

 

Off

On

Off

On

10

 

 

 

 

 

On

On

Off

On

11

 

 

 

 

 

Off

Off

On

On

12

 

 

 

 

 

On

Off

On

On

13

 

 

 

 

 

Off

On

On

On

14

 

 

 

 

 

On

On

On

On

15

 

 

 

 

 

With all four Index Select input functions inactive, Index number 0 will be initiated when the Index Initiate input function is activated. If you activate Index Select lines 0 and 1, Index number 3 (1 + 2 = 3) will be initiated when the Index Initiate function goes active. If you activate all four Index Select lines simultaneously, the selected Index number is 15 (1 + 2 + 4 + 8 = 15).

It is not necessary to assign all four Index Select input functions to input lines. Unassigned input functions are considered to be inactive. An application that only required four different indexes could assign Index Select 0 and 1 to input lines and leave Index 2 and 3 unassigned. The two input lines could then be used to select indexes 0, 1, 2 and 3.

Registration Sensor 1

This input function is usually used with an external hardware sensor. It is used as the registration reference in a registration index. If the option button on the registration tab on the Index View is set to Registration Sensor 1, then the registration offset portion of the index will begin when this input function is activated. Two registration sensor input functions have been provided for applications requiring multiple sensors.

Registration Sensor 2

This input function is usually used with an external hardware sensor. It is used as the registration reference in a registration index. If the option button on the registration tab on the Index View is set to Registration Sensor 2, then the registration offset portion of the index will begin when this input function is activated. Two registration sensor input functions have been provided for applications requiring multiple sensors.

Run Next Index

This input function is used when chaining indexes together, and the user wants to wait for an input to continue the chain, instead of starting the Next Index instantly. If “When this index is complete then” is set to “Wait for run next index input function”, then the current index will complete itself, and wait until this input function is activated to begin the next index in the chain.

Repeat Current Index

When the Repeat while Input Function active option button is selected on the Index view, an initiated index will continue to function until this input goes low.

Outputs

End Of Index

This output function is activated when any index is completed. This output function is deactivated when any Home, Jog or Index is initiated.

66

Page 78