Figure 32: Jog View

Jog and Jog Fast Velocity

The Jog Velocity parameter specifies the velocity used for jogging with the Jog + or Jog - input functions.

The Jog Fast Velocity parameter specifies the velocity used for fast jogging with the Jog Fast input function in conjunction with either the Jog + or Jog - input function.

Jog Acceleration and Deceleration

Jog acceleration and deceleration are in units of revs/) or user unit/sec2, depending on which Time Scale was selected on the User Units View. The default value for both is 1000 ms/kRPM. For example, at the default values, if you initiated a Jog with a velocity of 500 RPM, the motor will accelerate to 500 RPM in 0.5 seconds.

Accel Time = 500 RPM x 1000 ms/kRPM x 1 kRPM/1000 RPM = 500 msec = 0.5 sec

Jog Input Functions

The device has three input functions available which are used to initiate four different jogging operations: Jog+, Jog-, Jog Fast + and Jog Fast -.

Note

In the table below Jog Velocity = 100 RPM and Jog Fast Velocity = 500 RPM.

Jog +

Jog -

Jog Fast

Motion

Off

Off

Off

0 RPM

 

 

 

 

On

Off

Off

+100 RPM

 

 

 

 

Off

On

Off

-100 RPM

 

 

 

 

On

Off

On

+500 RPM

 

 

 

 

Off

On

On

-500 RPM

 

 

 

 

On

On

Off

0 RPM

 

 

 

 

On

On

On

0 RPM

 

 

 

 