Epsilon EP-I Indexing Drive and FM-2 Indexing Module Reference Manual

Figure 35: Home View

Home Type

The first step in setting up a home routine is to select the desired home type.

Standard Home

The device can home the motor to an external sensor, the motor’s encoder marker pulse or to a sensor and then to the encoder marker pulse.

One Side Home

The one side home is designed to add power to simple indexing applications where the machine can be stopped and re-homed from either side of the home sensor.

External Home

Sensor

Carriage

NT Motor

Sensor Rising Edge

Home Offset Distance (1.0 Revs)

Figure 36: Basic Standard Home Function

The figure above shows a basic standard home function using a ball screw. This example uses most of the setup features in the PowerTools Pro Home View.

44

Page 56
Image 56
Emerson P/N 400518-02 manual Standard Home, One Side Home