Display Indication | Status | Description |
| Stall Foldback | Drive output current is limited to 80 percent of drive stall current. |
| (EN drive only) | |
|
|
Ready to Run
Drive enabled, no Stop input.
Fault Codes
A number of diagnostic and fault detection circuits are incorporated to protect the drive. Some faults, like high DC bus and amplifier or motor over temperature, can be reset with the Reset button on the front of the drive or the Reset input function. Other faults, such as encoder faults, can only be reset by cycling power “Off” (wait until the diagnostics display turns “Off”), then power “On”.
The drive accurately tracks motor position during fault conditions. For example, if there is a “Low DC Bus” fault where the power stage is disabled, the drive will continue to track the motor’s position provided the logic power is not interrupted.
The +/- Limit faults are automatically cleared when the fault condition is removed. The table below lists all the fault codes in priority order from highest to lowest. This means that if two faults are active, only the higher priority fault will be displayed.
Display | Fault | Action to Reset | Bridge Disabled |
| Flash Invalid | Reprogram the Flash | Yes |
|
|
|
|
| Drive Overtemp | Allow Drive to Cool down, |
|
| Cycle Power or Cycle | Yes | |
| (Epsilon drive only) | ||
| Logic Power |
| |
|
|
| |
|
|
|
|
| Power Up Test | Cycle Power or Cycle | Yes |
| Logic Power | ||
|
|
| |
|
|
|
|
| NVM Invalid | Reset Button or Input Line | Yes |
|
|
|
|
| Invalid Configuration | Reset Button or Input Line | Yes |
|
|
|
|
| Power Module | Reset Button or Input Line | Yes |
| Cycle Logic Power (MDS) | ||
|
|
| |
|
|
|
|
| High DC Bus | Reset Button or Input Line | Yes |
|
|
|
|
| Low DC Bus | Reset Button or Input Line | Yes |
|
|
|
|
| Encoder State | Cycle Power or Cycle | Yes |
| Logic Power | ||
|
|
| |
|
|
|
|