Setting Up Parameters

Velocity View

This view allows the user to set the drive limits, and if online, view the velocity feedback parameters.

Figure 11: Velocity View - Online

Limits Group

Overspeed Velocity

This parameter specifies the maximum allowable speed. If the Velocity Feedback exceeds either the drive’s internal overspeed fault limit or the value of the Overspeed Velocity, an Overspeed Fault will be generated. The internal overspeed fault limit is equal to 150 percent of the Motor Maximum Operating Speed.

Trigger Group

In Motion Velocity

This parameter sets the activation point for both the In + Motion and In - Motion output functions. The output function will deactivate when the motor velocity slows to half of this value.

Online Tab

Velocity Group

All parameters in this group are only available when online with the device.

Velocity Command

The Velocity Command is the actual command received by the velocity loop.

Velocity Feedback

This parameter is the actual feedback motor velocity.

Analog Command Velocity

The drive is in Analog Velocity mode this parameter gives the current velocity commanded due to the Analog input function.

17

Page 29
Image 29
Emerson P/N 400518-02 manual Velocity View, Limits Group, Trigger Group, Online Tab Velocity Group