Epsilon
Online Tab
This tab is only available when online with the drive.
Velocity Group
Analog Command Velocity
When the drive is in Analog Velocity mode this parameter shows the current velocity commanded after the scaling of the Analog input function.
Velocity Command
This parameter is the velocity that the drive is commanding the motor to achieve. A properly tuned system should observe a velocity command that matches the velocity feedback.
Velocity Feedback
This parameter is the actual motor velocity feedback.
Torque Group
Analog Torque Command
This parameter displays the torque that is being commanded via the analog input.
Torque Command
This parameter displays the actual torque being required from the drive.
Torque Cmd Limited
This displays the percent of torque being commanded to the motor. This value is the result of the Torque Command after being limited by the current foldback and the Torque Limit value (if active).
Analog Input Group
Analog Input
This parameter displays the actual value of the analog input in volts.
Distance Recovery Group
Recovery Distance
This parameter stores the number of counts that have been lost during the accel portion of pulse mode. These pulses may be used to recover any distance lost during accel by selecting the Enable Distance Recovery check box.
Pulse Input Posn
This parameter is the total number of actual pulses received on the pulse input hardware.
Status Group
Alternate Mode Enabled
This virtual LED will be green when the Alternate Mode Enable Input is active.
Velocity Limiting Active
The virtual LED is green when velocity limiting is active.
Alternate Mode Input and Output Functions
Alternate Mode Enable
This is a level sensitive function and may be enabled using Input assignments or through Modbus. Alternate Mode Enable allows the drive to run in either Pulse Mode, Analog Velocity Mode, or Analog Torque Mode.
Torque at Max Velocity
This output while in Torque mode, indicates that the motor is velocity limited.
76