Epsilon EP-I Indexing Drive and FM-2 Indexing Module Reference Manual

Time Scale Group

Time Base

Select either minute or second as the time scale for the configuration. The default time scale is minutes. If the selected time scale is seconds, then the velocity units will appear as

user units/sec. If the selected time scale is minutes, the velocity units will appear as user units/minute.

If the selected time scale is seconds, then the accel/decel units will appear as user units/sec2. If the selected time scale is minutes, the accel/decel units will appear as

msec/(1000 (user units)/min) or msec/(k (user units)/min). Therefore, for accel/decel units, the default is msec/kRPM (the same as previous versions of the FM-2 module).

Acceleration Group

Decimal Places

This will specify the number of digits after the decimal place to be used in all Acceleration/Deceleration parameters.

Position View

The Position View allows you to set up and view the parameters related to drive positioning. In, Position has been selected in the Hierarchy Tree. The right side of the view is divided into groups. An explanation of the groups and their functions is provided below.

Figure 10:

Position View

Index In Position Group

In Position

The In Position (InPosn) source will activate at the end of a move if the absolute value of following error is less than or equal to the In Position Window for the In Position Time.

In Position Window

The absolute value of the Following Error must be less than or equal to this value at the end of an index in order for the InPosn source to activate. This window is set in units specified in the User Units View.

For example:

The In Position window is set to 0.0025 revs. At the end of an index, the following error is calculated to be 0.0012 revolutions. Therefore, the InPosn output will activate.