Alliance Laundry Systems CHM1772C manual Installation, Machine Foundation

Models: CHM1772C

1 57
Download 57 pages 51.99 Kb
Page 24
Image 24
Installation

Installation

Machine Foundation

NOTE: Do not mount on wooden floors, tile floors, above ground level, or over basements or crawl spaces because of the high extract speed and the G-forces exerted.

Thoroughness of detail must be stressed with all foundation work to ensure a stable unit installation, eliminating possibilities of excessive vibration during the extract cycle.

The floor and foundation must be minimum 4000 psi reinforced concrete set firmly in clean, compacted fill dirt.

The machine must be anchored to a smooth, level surface so that the entire base of the machine is supported and rests on the mounting surface. (Do not support the machine on only four points.)

Grouting is required.

An elevated foundation must not exceed 8 inches (203 mm).

Refer to Table 1 for foundation and anchoring requirements.

Machine Foundation Requirements

 

 

Foundation

Mounting

Installation

Anchoring

Anchoring

Models

Bolt

Thickness

Bolt

Foundation

Method(s)

Diameter

 

 

(minimum)

depth

Method(s)

Requirement*

Size

 

 

 

 

 

 

(minimum)

2 Speed and F-Speed

4 in.

2.75 in.

Direct-to-floor, elevated

Expansion bolt

5/8 in.

(20-60 Models)

(102 mm)

(70 mm)

base frame, or concrete

or Epoxy bolt

 

 

 

 

 

foundation

 

 

 

 

 

 

 

 

Variable-Speed

6 in.

2.75 in.

Direct-to-floor, elevated

Epoxy bolt

5/8 in.

(20-60 Models)

(152 mm)

(70 mm)

base frame or concrete

 

 

 

 

 

 

foundation

 

 

 

 

 

 

 

 

 

 

80 Models

9 in.

3.25 in.

Direct-to-floor or

Epoxy bolt or

3/4 in.

Variable-

(229 mm)

(83 mm)

concrete foundation

rebar frame

 

 

 

Speed

 

 

 

 

 

 

125 Models

12 in.

3.25 in.

 

 

 

 

 

 

 

 

(304 mm)

(83 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Recommend SAE 495 Grade 5 or higher strength bolts.

Table 1

WARNING

To reduce the risk of fire, this appliance must be bolted to an uncovered concrete floor.

W731

22

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8208301