Installation

Electrical Specifications

60 Pound Capacity Models

 

Voltage Designation

 

 

 

Standard

 

 

Electric Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

Voltage

Cycle

 

Phase

Wire

FullLoad Amps

Circuit Breaker

AWG

2

FullLoad Amps

Circuit Breaker

 

AWG

2

 

 

 

 

 

 

 

 

 

mm

 

 

 

 

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Speed and Fixed-Speed Models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

380-415

50

 

3

4

5

15

14

2.5

27

30

 

10

6.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

440-480

60

 

3

3

5

15

14

2.5

24

30

 

10

6.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

200

50

 

3

3

10

20

12

4.0

 

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

208-240

60

 

3

3

10

20

12

4.0

48

50

 

8

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable-Speed Models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

380-480

50/60

 

3

3

6

15

14

2.5

23

30

 

10

6.0

(through

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/6/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

440 – 480

60

 

3

3

6

15

14

2.5

24

30

 

10

6.0

(starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/7/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380 – 415

50

 

3

3

6

15

14

2.5

24

30

 

10

6.0

(starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/7/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50/60

 

3

3

8

15

14

2.5

43

50

 

8

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

200-240

50/60

 

1/3

2/3

11/8

15

14

2.5

 

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.