Specifications and Dimensions

2 Speed Models (Continued)

Specification

 

 

20

30

40

60

 

 

 

 

 

 

Direct Steam Heating (Optional)

 

 

 

 

 

 

 

 

 

Steam inlet connection size, NPT

 

N/A

N/A

1/2

1/2

 

 

 

 

 

 

 

Number of steam inlets

 

 

N/A

N/A

1

1

 

 

 

 

 

 

 

Steam required to raise bath

LOW

 

N/A

N/A

2.09

3.6

water temperature,

 

(0.84)

(0.895)

 

 

 

 

10°F (10°C), lbs. (kg)

 

 

 

 

 

 

MED

 

N/A

N/A

2.40

4.4

 

 

 

 

 

(1.15)

(1.384)

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

N/A

N/A

2.84

5.5

 

 

 

(1.48)

(1.916)

 

 

 

 

 

 

 

 

 

 

 

 

Average steam use per cycle,

 

 

N/A

0.73

1.43

2.32

bhp (kg)

 

 

(6.9)

(12.2)

(15.4)

 

 

 

 

 

 

 

 

 

Electrical Heating (Optional)

 

 

 

 

 

 

 

 

 

 

 

Total electrical heating

Input Voltage

 

 

 

 

capacity, kW

 

 

 

 

 

 

200V

 

5.4

5.4

10.8

10.8

 

 

 

 

 

 

 

 

 

 

240V

 

7.8

7.8

15.6

15.6

 

 

 

 

 

 

 

 

380V

 

6.5

6.5

13.0

13.0

 

 

 

 

 

 

 

 

415V

 

7.8

7.8

15.5

15.5

 

 

 

 

 

 

 

 

480V

 

10.4

10.4

15.6

15.6

 

 

 

 

 

 

 

Electrical heating elements

 

 

3

3

6

6

 

 

 

 

 

 

Electrical heat element size, kW

 

2.6

2.6

2.6

2.6

 

 

 

 

 

 

 

14

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8208301