Installation

2

L1

L2 IMPORTANT: Do not use a phase adder on any machine.Thermal Overload ProtectorManual backgroundManual backgroundManual backgroundManual backgroundManual background

1L3 Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

SERVICE

CHASIS

GROUND

3

TB1

MACHINES WITH ELECTRIC HEAT

PHM

 

 

PHM700N

1Grounding Lug: Connect to proven earth ground

2Customer Input Power Terminals

3Internal Load Distribution - DO NOT connect customer power source or load.

Figure 27

1

SERVICE

CHASIS

GROUND

2

Manual backgroundL1

L2

L3

TB1

MACHINES WITHOUT ELECTRIC HEAT

P

 

 

PHM721N

1Grounding Lug: Connect to proven earth ground

2Customer Input Power Terminals

Figure 28

Machines can be converted for lower voltage operation and/or 50 Hz operation. Refer to conversion label by serial plate for details.

Phase Adder

IMPORTANT: Do not use a phase adder on any machine.

Thermal Overload Protector

Two speed machines have thermal overload protectors in drive motor windings. For variable-speed machines, the AC drive provides overload protection for the drive motor.