Basic Installation/Operation

Table 1 (continued)

Specifications

35

60

80

100

125

150

 

 

 

 

 

 

 

Direct Steam Heating (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

Steam inlet connection size,

0.5 (13)

0.5 (13)

0.5 (13)

0.5 (13)

0.75 (19)

0.75 (19)

in (mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of steam inlets

 

1

1

1

1

1

1

 

 

 

 

 

 

 

 

Steam required to

LOW

2.1 (1.5)

3.3 (2.4)

4.6 (3.3)

5.7 (4.1)

6.7 (4.9)

8.3 (6.0)

raise bath temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10°F, lb (10°C, kg)

MED

2.3 (1.7)

3.7 (2.6)

5.2 (3.8)

6.5 (4.7)

7.8 (5.6)

9.5 (6.9)

 

 

 

 

 

 

 

 

 

HIGH

2.7 (1.9)

4.1 (2.9)

6.1 (4.4)

7.6 (5.5)

9.1 (6.6)

11.1 (8.0)

 

 

 

 

 

 

 

 

Average consumption per

1.4 (21.4)

2.1 (33.4)

3.1 (48.4)

3.8 (60.4)

4.6 (72.0)

5.8 (91.0)

cycle, BHP (kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Heating (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

Total electrical heating

 

15.6

27.4

41.2 (Q-Volt)

41.2 (Q-Volt)

N/A

N/A

capacity, kW (N/A for 2-speed

 

 

27.4 (N-Volt)

27.4 (N-Volt)

 

 

models)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of electrical heating

6

6

9

9

N/A

N/A

elements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical heating element size,

2.6

4.2

4.2

4.2

N/A

N/A

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time required to

LOW

2.4 (3.6)

2.4 (3.7)

2.2 (3.4)

2.8 (4.2)

N/A

N/A

raise bath temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10°F, min (5°C, min)

MED

2.7 (4.1)

2.7 (4.1)

2.5 (3.9)

3.2 (4.8)

N/A

N/A

 

 

 

 

 

 

 

 

 

HIGH

3.1 (4.7)

3.0 (4.6)

3.0 (4.5)

3.7 (5.6)

N/A

N/A

 

 

 

 

 

 

 

 

Table 1

8

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232156

Page 10
Image 10
Alliance Laundry Systems P232156R9 manual Electrical Heating Optional