Basic Installation/Operation

Table 2 (continued)

UWAV Pocket Hardmount General Specifications

Specifications

 

 

35

60

80

100

125

 

 

 

 

 

 

 

Drive Train Information

 

 

 

 

 

 

 

 

 

 

 

Number of motors in drive train

 

1

1

1

1

1

 

 

 

 

 

 

 

 

Drive motor power, hp (kW)

 

 

2.3 (1.7)

2.9 (2.2)

5.0 (3.7)

5.0 (3.7)

7.5 (5.6)

 

 

 

 

 

 

Cylinder Speeds / Centrifugal Force Data

 

 

 

 

 

 

 

 

 

 

 

 

1/2 Wash/reverse, RPM / g

 

 

26 / .25

26 / .31

26 / .35

26 / .35

26 / .40

 

 

 

 

 

 

 

 

Wash/reverse, RPM / g

 

 

42 / .66

40 / .73

40 / .82

40 / .82

37 / .82

 

 

 

 

 

 

 

 

Distribution, RPM / g

 

 

83 / 2.57

71 / 2.29

73 / 2.57

70 / 2.50

62 / 2.29

 

 

 

 

 

 

 

 

High extract 1, RPM / g

 

 

329 / 40

297 / 40

280 / 40

280 / 40

260 / 40

 

 

 

 

 

 

 

 

High extract 2, RPM / g

 

 

534 / 106

483 / 106

456 / 106

456 / 106

422 / 106

 

 

 

 

 

 

 

 

High extract 3, RPM / g

 

 

656 / 160

594 / 160

560 / 160

560 / 160

518/ 160

 

 

 

 

 

 

 

 

Balance Detection

 

 

 

 

 

 

 

 

 

 

 

 

 

Vibration safety switch installed

 

N/A

STD

STD

STD

STD

 

 

 

 

 

 

 

Safety switch gap setting, in. (mm)*

 

N/A

.25 (.010) NO-GO

.25 (.010) NO-GO

.25 (.010) NO-GO

.20 (.008) NO-GO

 

 

 

 

.20 (.008) GO

.20 (.008) GO

.20 (.008) GO

.15 (.006) GO

 

 

 

 

 

Direct Steam Heating (Optional)

 

 

 

 

 

 

 

 

 

 

Steam inlet connection size, in. (mm)

 

.5 (13)

.5 (13)

.5 (13)

.5 (13)

.75 (19)

 

 

 

 

 

 

 

 

Number of steam inlets

 

 

1

1

1

1

1

 

 

 

 

 

 

 

 

Steam required to raise bath

 

LOW

 

2.1 (1.5)

3.3 (2.4)

4.6 (3.3)

5.7 (4.1)

6.7 (4.9)

temperature,

 

 

 

 

 

 

 

 

 

MED

 

2.3 (1.7)

3.7 (2.6)

5.2 (3.8)

6.5 (4.7)

7.8 (5.6)

10°F, lb. (10°C, kg)

 

 

 

 

HIGH

 

2.7 (1.9)

4.1 (2.9)

6.1 (4.4)

7.6 (5.5)

9.1 (6.6)

 

 

 

 

 

 

 

 

Average consumption per cycle, bhp

 

1.4 (21.4)

2.1 (33.4)

3.1 (48.4)

3.8 (60.4)

4.6 (72.0)

(kg)

 

 

 

 

 

 

 

Electrical Heating (Optional)

 

 

 

 

 

 

 

 

 

 

 

Total electrical heating capacity, kW

 

15.6

25.2

37.8

37.8

50.4

 

 

 

 

 

 

 

Number of electrical heating elements

 

6

6

9

9

12

 

 

 

 

 

 

 

Electrical heating element size, kW

 

2.6

4.2

4.2

4.2

4.2

 

 

 

 

 

 

 

 

Time required to raise bath

 

LOW

 

2.4 (3.6)

2.4 (3.7)

2.2 (3.4)

2.8 (4.2)

2.5 (3.8)

temperature,

 

 

 

 

 

 

 

 

 

MED

 

2.7 (4.1)

2.7 (4.1)

2.5 (3.9)

3.2 (4.8)

2.9 (4.4)

10°F, min. (10°C, min.)

 

 

 

 

HIGH

 

3.1 (4.7)

3.0 (4.6)

3.0 (4.5)

3.7 (5.6)

3.4 (5.1)

 

 

 

 

 

 

 

 

 

* Gap setting should be made with “GO/NO-GO” type feeler gauge.

Table 2

10

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232156

Page 12
Image 12
Alliance Laundry Systems P232156R9 manual Med