Basic Installation/Operation
Table 4 (continued)
UW 2 Speed Models
|
| UW35 | UW60 | |
|
|
|
| |
Drive Train Information |
|
|
| |
|
|
|
| |
Number of motors in drive train |
| 1 | 1 | |
|
|
|
| |
Wash/reverse motor power, HP (kW) |
| 0.4 (0.3) | 0.6 (0.5) | |
|
|
|
| |
High extract motor power, HP (kW) |
| 1.8 (1.3) | 3.0 (2.2) | |
|
|
| ||
Cylinder Speeds/Centrifugal Force Data |
|
| ||
|
|
|
| |
Wash/reverse speed, RPM / g |
| 50 / 0.95 | 44 / 0.88 | |
|
|
|
| |
Distribution speed, RPM / g |
| – | – | |
|
|
|
| |
High extract speed, RPM / g |
| 504 / 95 | 465 / 98 | |
|
|
|
| |
Balance Detection |
|
|
| |
|
|
|
| |
Vibration safety switch installed |
| N/A | STD | |
|
|
|
| |
Safety switch gap setting, in. (mm) |
| N/A | ||
|
|
|
| |
Direct Steam Heating (Optional) |
|
|
| |
|
|
|
| |
Steam inlet connection size, in. (mm) |
| 1/2 (13) | 1/2 (13) | |
|
|
|
| |
Number of steam inlets |
| 1 | 1 | |
|
|
|
| |
Steam required to raise bath temperature, | LOW | 2.1 (1.5) | 3.3 (2.4) | |
10°F, lb. (10°C, kg) |
|
|
| |
MED | 2.3 (1.7) | 3.7 (2.6) | ||
| ||||
|
|
|
| |
| HIGH | 2.7 (1.9) | 4.1 (2.9) | |
|
|
|
| |
Average consumption per cycle, bhp (kg/hr) |
| 1.4 (21.4) | 2.1 (33.4) | |
|
|
|
| |
Electrical Heating (Optional) |
|
|
| |
|
|
|
| |
Total electrical heating capacity, kW |
| 15.6 | 25.2 | |
|
|
|
| |
Number of electrical heating elements |
| 6 | 6 | |
|
|
|
| |
Electrical heating element size, kW |
| 2.6 | 4.2 | |
|
|
|
| |
Time required to raise bath temperature, | LOW | 2.4 (3.6) | 2.4 (3.7) | |
10°F, min. (10°C, min.) |
|
|
| |
MED | 2.7 (4.1) | 2.7 (4.1) | ||
| ||||
|
|
|
| |
| HIGH | 3.1 (4.7) | 3.0 (4.6) | |
|
|
|
|
Table 4
14 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232156 |