Gas Requirements

Pressure checks can be made at the shut-off valve (refer to Figure 14).

Turn on gas and check all pipe connections (internal and external) for gas leaks with a non-corrosive leak detection fluid.

Purge air in gas service line by operating the tumbler in the drying mode.

If burner does not light and unit goes into lockout, open and close the door and restart. Repeat these steps until burner ignites. Use pipe compound, resistant to actions of L.P. Gas, on all pipe threads.

WARNING

Check all pipe connections, internal and external, for gas leaks using a non- corrosive leak detection fluid. To reduce the risk of explosion or fire, DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS! Gas connections should be checked annually for leakage.

W314

36

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

M414038