Loading Door Strike

The door strike must be adjusted to have sufficient tension to hold loading door closed against force of load tumbling against it. Proper adjustment is when 8-15 pounds (35.6-66.7 N) pull is required to open door.

If adjustment is required, refer to Figure 25 and proceed as follows:

To adjust, open door, loosen jam nut and turn door strike screw in or out as required. Retighten jam nut.

1

2

3

T048I

1Door Strike

2Door Latch

3Jam Nut

Figure 25

Adjustments

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

Disconnect electric power to the tumbler before servicing.

Close gas shut-off valve to gas tumbler before servicing.

Close steam valve to steam tumbler before servicing.

Never start the tumbler with any guards/ panels removed.

Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.

W002

M414038

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

53