InstallationLocation Requirements

The tumbler must be installed on a level floor capable of supporting 120 lbs./ft2 (585.8 kg/m2). Floor covering materials such as carpeting or tile should be removed.

To assure compliance, consult local building code requirements.

The tumbler MUST NOT be installed or stored in area where it will be exposed to water and/or weather.

IMPORTANT: DO NOT block the airflow at the rear of the tumbler with laundry or other articles. Doing so would prevent adequate air supply to the combustion chamber of the tumbler.

A typical tumbler enclosure is shown in Figure 1. Note that the enclosure touches the tumbler top and side panels. Also, note the minimum and maximum dimensions. Local codes and ordinances must be complied with.

WARNING

To reduce the risk of serious injury, install lockable door(s) to prevent public access to rear of tumblers.

W055

IMPORTANT: Install tumblers with sufficient clearance for servicing and operation. Refer to Figure 1.

WARNING

To reduce the risk of severe injury, clearance of tumbler cabinet from combustible construction must conform to the minimum clearances.

W056

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

7

4

5

6

TMB237N

NOTE: Shaded areas indicate adjacent structure.

1Zero clearance permitted for first 4 in. (102 mm)

24 in. (102 mm)

3Minimum clearance permitted for remainder: Gas 4 in. (102 mm), Steam 12 in. (305 mm)

4Guard

5Provision for Make-Up Air

624 in. (610 mm) Minimum, 36 in. (914 mm) recommended for maintenance purposes

7Zero Clearance

Figure 1

18