4.3 Error Messages
Storage error codes
Hard disk errors
Code Meaning
01Hard disk format error. If this error recurs even if the power has been turned off and then on, reformat the hard disk.
02The disk system is not installed. Recheck the requirements for using the system and the devices.
04There is no available hard disk space. Delete unnecessary files, etc., in order to free up space.
06There is no memory available to the hard disk system. Increase the available memory.
10Formatting is not possible because host data is being spooled on the hard disk. Wait until the hard disk is ready, and then format.
85VMB: Alias error. The alias setting was lost, or the virtual tray corresponding to the alias does not exist. Set the alias again.
97The number of permanent code jobs that can be stored reached the limit value, and no more can be saved. Either delete some unnecessary jobs, etc., or increase the limit.
98An unreadable page was found in a job (The job is damaged.).
99A print job for the specified ID does not exist in the hard disk.
Table
Memory card errors
Code Meaning
01The printer does not support the memory card inserted. The memory card must meet the requirements described in A.3.1 Memory Card on page
02The memory card is not installed.
04The memory card is full and cannot hold further data. Purge unnecessary files or use a new memory card.
06Insufficient printer memory to support the memory card system. Expand printer memory.
Table
RAM disk errors
Code Meaning
01Format error. Try turning the power off and on again.
02RAM disk mode is Off. Turn RAM disk mode On from the operator panel.
04No disk space. Purge unnecessary files.
06Insufficient printer memory to support the RAM disk system. Expand printer memory.
Table