Anritsu 373XXA manual Table B-3.GPIB-Related Error Messages 4

Models: 373XXA

1 202
Download 202 pages 15.37 Kb
Page 167
Image 167

APPENDIX B

SERVICE LOG ERROR MESSAGES

Table B-3.GPIB-Related Error Messages (4 of 8)

Error Message

Description

 

 

Current and cal frequencies dif-

The flat power calibration setup does not match the current setup.

ferent

 

 

 

Stored data is invalid

An attempt was made to reference normalized data when normalized data was invalid.

 

 

Parameter change not permitted

An attempt was made to change a parameter while IF cal was active. It is not ex-

on current state

pected that this message will ever be seen. If you see this message, notify the fac-

 

tory.

 

 

Calibration may not be valid

An attempt was made to repeat the previous calibration when there was no record of a

 

previous calibration.

 

 

Calibration does not exist

An attempt was made to turn on flat power correction or vector error correction when

 

the corresponding calibration does not exist.

 

 

Current calibration is erased

When turning on Multiple Source Mode with vector error correction on, the calibration

 

is destroyed. Not really an error. Message is issued as a warning.

 

 

Time Domain and CW mode not

An attempt was made to turn on a time domain mode in CW. This is not permitted.

permitted

 

 

 

Not permitted in Time Domain

An attempt was made to select a group delay display or CW mode when in time do-

 

main mode or to select a dual overlay display with a frequency/time domain mismatch.

 

 

Time Domain not allowed

An attempt was made to turn on a time domain mode but the current 373XXA state

 

does not permit it.

 

 

Permitted only in diagnostic

Must put the 373XXA into the diagnostics mode via the SDG command before using

mode

this mnemonic.

 

 

Graph types not appropriate for

While in dual overlay mode, and attempt was made to change one of the active graph

dual overlay

types to a type which conflicts with dual overlay, or to change one of the active chan-

 

nels into or out of time domain which sets up a dual overlay conflict. Or an attempt

 

was made to select dual overlay mode when there would be a graph type conflict for a

 

frequency/time domain conflict.

 

 

New Discrete Fill not allowed in

Cannot set up a new discrete fill definition while performing a calibration or when cor-

current state

rection is turned on. Also cannot do this when group delay is the graph type on the

 

active channel.

 

 

Low Pass mode requires a har-

Perform a TD harmonic sweep calibration prior to using this mnemonic.

monic sweep

 

 

 

Receiver out of range by equa-

Problems with the internal source, external source or receiver equations in multiple

tion

source mode.

 

 

New start less than previous

An attempt was made to set the start frequency for the new multiple source mode

stop

band definition to a frequency less than the stop frequency of the previous band.

 

 

373XXA MM

B-11

Page 167
Image 167
Anritsu 373XXA manual Table B-3.GPIB-Related Error Messages 4

373XXA specifications

The Anritsu 373XXA series is a notable line of microwave and RF signal analyzers designed for comprehensive analysis and testing of various wireless communication technologies. These analyzers are specifically crafted to meet the demands of modern communication systems, making them ideal for engineers and technicians working in wireless research, development, and manufacturing.

One of the main features of the Anritsu 373XXA series is its wide frequency range, which typically spans from as low as 5 kHz to several GHz, accommodating a vast array of signal types and applications. This extensive frequency coverage allows users to test and validate all manner of systems, from LTE and 5G networks to satellite communications, yielding accurate and reliable measurement results.

The device employs advanced measurement technologies that provide in-depth analysis capabilities. Among these technologies is the ability to perform both time and frequency domain measurements, allowing users to visualize and diagnose signal integrity issues effectively. In addition, the 373XXA series incorporates vector signal analysis, which is crucial in evaluating complex modulated signals, commonly found in today’s sophisticated wireless communication protocols.

Another distinguishing characteristic of the Anritsu 373XXA is its user-friendly interface. It features a large, high-resolution display that enables easy navigation through the analyzer's functions and measurements. The intuitive design is further enhanced by customizable settings and measurement configurations that streamline the workflow, making it accessible for both novice and experienced users.

The 373XXA series also supports various digital and analog signal demodulation techniques, ensuring compatibility with an array of communication standards. Furthermore, users can benefit from its built-in signal generation capabilities, which allows for end-to-end testing of devices and systems under realistic operational conditions.

Portability is another key feature of the Anritsu 373XXA series. The compact design and lightweight structure facilitate easy transport, which is particularly advantageous for field applications where mobility is critical.

Overall, the Anritsu 373XXA series stands out as a versatile and powerful tool for professionals in the RF and microwave field, thanks to its extensive frequency range, advanced measurement technologies, user-friendly interface, and portability. Whether developing new wireless standards or troubleshooting existing systems, the 373XXA delivers precision and reliability essential for today’s dynamic communication landscape.