Anritsu 373XXA manual Gpib Device Dependent Error Descriptions

Models: 373XXA

1 202
Download 202 pages 15.37 Kb
Page 170
Image 170

SERVICE LOG ERROR MESSAGES

APPENDIX B

Table B-3.GPIB-Related Error Messages (7 of 8)

Error Message

Description

 

 

Response after Indefinite Re-

This error is generated when the 373XXA’s output queue has already received an Ar-

sponse discarded

bitrary ASCII response data element and an attempt is made to place another re-

 

sponse data element of any kind into the queue. The new response data element is

 

discarded.

 

 

Interrupted - Response data dis-

This error is detected when the output queue contains unread response data and the

carded

controller sends a new program message. The response data is discarded.

 

 

Unterminated - Partial PM will be

This error is detected when the 373XXA’s input queue is currently receiving a program

executed

message but has not yet received the end message, and the controller attempts to

 

read response data from the 373XXA. The partial program message in the input

 

queue is executed as if it were properly terminated.

 

 

Deadlock - Response data dis-

This error is detected when both of the 373XXA’s input and output queues are full and

carded

the controller attempts to send another data byte. In order to prevent bus deadlock,

 

the contents of the output queue are discarded.

 

 

 

7205 GPIB DEVICE DEPENDENT ERROR DESCRIPTIONS

 

 

Q_SEND failure in [a procedure

An unsuccessful attempt was made to send a message to a task.

name]

 

 

The procedure name is the place in the software where the error was detected.

 

 

Q_RECEIVE failure in [a proce-

A failure was detected while waiting for the reception of a message from a task.

dure name]

 

 

The procedure name is the place in the software where the error was detected.

 

 

Unable to allocate memory in [a

An attempt was made to allocate some temporary memory in order to accomplish a

procedure name]

task directed in the program message.

 

The procedure name is the place in the software where the error was detected.

 

 

Unable to release memory in [a

An attempt was made to return some temporary memory within a task and the return

procedure name]

failed for some reason.

 

The procedure name is the place in the software where the error was detected.

 

 

Unable to get service/error log

An unsuccessful attempt was made to get a copy of the service or error log.

 

 

Unable to get calibration term

An unsuccessful attempt was made to get a calibration term.

 

 

Unable to get raw or corrected

An unsuccessful attempt was made to get raw or corrected data.

data

 

Unable to get final data

An unsuccessful attempt was made to get final data.

Unable to get setup or data

An unsuccessful attempt was made to get the frequency list from the database.

Unable to get setup

An unsuccessful attempt was made to get a front panel setup.

B-14

373XXA MM

Page 170
Image 170
Anritsu 373XXA manual Gpib Device Dependent Error Descriptions

373XXA specifications

The Anritsu 373XXA series is a notable line of microwave and RF signal analyzers designed for comprehensive analysis and testing of various wireless communication technologies. These analyzers are specifically crafted to meet the demands of modern communication systems, making them ideal for engineers and technicians working in wireless research, development, and manufacturing.

One of the main features of the Anritsu 373XXA series is its wide frequency range, which typically spans from as low as 5 kHz to several GHz, accommodating a vast array of signal types and applications. This extensive frequency coverage allows users to test and validate all manner of systems, from LTE and 5G networks to satellite communications, yielding accurate and reliable measurement results.

The device employs advanced measurement technologies that provide in-depth analysis capabilities. Among these technologies is the ability to perform both time and frequency domain measurements, allowing users to visualize and diagnose signal integrity issues effectively. In addition, the 373XXA series incorporates vector signal analysis, which is crucial in evaluating complex modulated signals, commonly found in today’s sophisticated wireless communication protocols.

Another distinguishing characteristic of the Anritsu 373XXA is its user-friendly interface. It features a large, high-resolution display that enables easy navigation through the analyzer's functions and measurements. The intuitive design is further enhanced by customizable settings and measurement configurations that streamline the workflow, making it accessible for both novice and experienced users.

The 373XXA series also supports various digital and analog signal demodulation techniques, ensuring compatibility with an array of communication standards. Furthermore, users can benefit from its built-in signal generation capabilities, which allows for end-to-end testing of devices and systems under realistic operational conditions.

Portability is another key feature of the Anritsu 373XXA series. The compact design and lightweight structure facilitate easy transport, which is particularly advantageous for field applications where mobility is critical.

Overall, the Anritsu 373XXA series stands out as a versatile and powerful tool for professionals in the RF and microwave field, thanks to its extensive frequency range, advanced measurement technologies, user-friendly interface, and portability. Whether developing new wireless standards or troubleshooting existing systems, the 373XXA delivers precision and reliability essential for today’s dynamic communication landscape.