APPENDIX D

PERFORMANCE SPECIFICATIONS

Where kW is two times the number of window terms (for example, four for a two-term window)

For a 40 GHz sweep range with 1601 data points, the unaliased range is 40.025 nanoseconds.

For a 65 GHz sweep with 1601 data points, the unaliased range is 24.646 nanoseconds.

Frequency with Time Gate: Data that has been con- verted to time domain and selected by the application of gating function may be converted back to the frequency domain. This allows the display of the frequency response of a single element contained in the device under test. Fre- quency response accuracy is a function of window and gate type, and gate width. For a full reflection, minimum gate and window accuracy is within 0.2 dB of the ungated response over a 40 GHz range.

MEASUREMENT UNCERTAINTY

The graphs on pages D-13through D-15give measure- ment accuracy after 12-term vector error correction. The errors are worst case contributions of residual directivity, load and source match, frequency response, isolation, net- work analyzer dynamic accuracy, and connector repeatabil- ity. In preparing the following graphs, 10 Hz IF bandwidth and averaging of 512 points were used (measured at

23￿3￿ C). Changes in the IF bandwidth or averaging can result in variations at low levels.

SYSTEM OPTIONS

OPTION 1, Rack Mounting: Rack mount kit containing a set of track slides (90 tilt capability), mounting ears, and front panel handles to let the instrument be mounted in a standard 19-inch equipment rack.

OPTION 1A, Rack Mounting: Rack mounting kit contain- ing a set of mounting ears and hardware to permanently mount instrument in a standard 19-inch equipment rack.

OPTION 2, High Speed Time (Distance) Domain Measurement Capability

OPTION 4, External SCSI-2 Hard Disk Drive Compatibil-

ity: Provides SCSI-2 rear panel connector for connection of an external SCSI HDD. Remove internal HDD.

OPTION 7A/N/NF/S/K, Universal Test Port Configura- tion Replaces Universal/K Connector (standard) with:

7A - Universal/GPC-7

7N - Universal/N, male 7NF - Universal/N, female

7S - Universal/3.5 mm, male

OPTION 10A, High Stability Time Base: Replaces the standard temperature compensated crystal oscillator (with a temperature stability of 1ppm over a 0 to 55 ￿C range)with an ovenized crystal oscillator (aging stability of 1 x 10-9/day and temperature stability 5 x 10-9over 0 to 55 ￿C range). Adds 1 Hz frequency resolution.

UPGRADE OPTIONS*

37200A Upgrade to a higher frequency 37200A.

37200A Upgrade to an equivalent or higher frequency

37300A.

37200B Upgrade to a higher frequency 37200B.

37200B Upgrade to an equivalent or higher frequency

37300A.

37300A Upgrade to a higher frequency 37300A.

Please call your Anritsu representatives for pricing and de- livery.

 

 

ON-SITE SUPPORT

Option ES 31:

3

year on-site repair.

Option ES 37:

3

year on-site verification

Option ES 38:

3

year on-site Mil-Std verification

Option ES 51:

5

year on-site repair.

Extended Service Options Additional, two year and four year return to Anritsu service is available, as an option for 373XXA systems and components. Prices and details are available from your Sales Representative or by contacting the factory.

CALIBRATION KITS

Standard

3650 SMA/3.5 mm Calibration Kit

Option 1: Male and Female Sliding Terminations

3651 GPC-7 Calibration Kit

Option 1: Sliding Terminations

3652 K Connector Calibration Kit

Option 1: Male and Female Sliding Terminations

3653 Type N Calibration Kit

3654B Type V Calibration Kit; includes male & female

sliding terminations

Economy (8.6 GHz)

3750

SMA Calibration Kit

3751

GPC-7 Calibration Kit

3753

Type N, 50

W, Calibration Kit

3753-75 Type N,

75 , Calibration Kit

VERIFICATION KITS

3663 Type N Verifications Kit

3666 3.5 mm Verifications Kit

3667 GPC–7 Verifications Kit

3668 K Connector Verifications Kit

3669B V Connector Verifications Kit

SEMI-RIGID TEST PORT CABLES

3670A50-1,DC to 18 GHz, GPC–7 connectors, 1 foot long, two required.

3670A50-2,DC to 18 GHz, GPC–7 connectors, 2 feet long.

3670K50-1,DC to 40 GHz, K connectors, 1 foot long, male/female, two required.

3670K50-2,DC to 40 GHz, K connectors, 2 feet long, male/female.

373XXA MM

D-11

Page 190
Image 190
Anritsu 373XXA manual Option ES, Standard 3650 SMA/3.5 mm Calibration Kit, GPC-7 Calibration Kit, Connector Calibration Kit

373XXA specifications

The Anritsu 373XXA series is a notable line of microwave and RF signal analyzers designed for comprehensive analysis and testing of various wireless communication technologies. These analyzers are specifically crafted to meet the demands of modern communication systems, making them ideal for engineers and technicians working in wireless research, development, and manufacturing.

One of the main features of the Anritsu 373XXA series is its wide frequency range, which typically spans from as low as 5 kHz to several GHz, accommodating a vast array of signal types and applications. This extensive frequency coverage allows users to test and validate all manner of systems, from LTE and 5G networks to satellite communications, yielding accurate and reliable measurement results.

The device employs advanced measurement technologies that provide in-depth analysis capabilities. Among these technologies is the ability to perform both time and frequency domain measurements, allowing users to visualize and diagnose signal integrity issues effectively. In addition, the 373XXA series incorporates vector signal analysis, which is crucial in evaluating complex modulated signals, commonly found in today’s sophisticated wireless communication protocols.

Another distinguishing characteristic of the Anritsu 373XXA is its user-friendly interface. It features a large, high-resolution display that enables easy navigation through the analyzer's functions and measurements. The intuitive design is further enhanced by customizable settings and measurement configurations that streamline the workflow, making it accessible for both novice and experienced users.

The 373XXA series also supports various digital and analog signal demodulation techniques, ensuring compatibility with an array of communication standards. Furthermore, users can benefit from its built-in signal generation capabilities, which allows for end-to-end testing of devices and systems under realistic operational conditions.

Portability is another key feature of the Anritsu 373XXA series. The compact design and lightweight structure facilitate easy transport, which is particularly advantageous for field applications where mobility is critical.

Overall, the Anritsu 373XXA series stands out as a versatile and powerful tool for professionals in the RF and microwave field, thanks to its extensive frequency range, advanced measurement technologies, user-friendly interface, and portability. Whether developing new wireless standards or troubleshooting existing systems, the 373XXA delivers precision and reliability essential for today’s dynamic communication landscape.