Gas Requirements

Instant Electronic Ignition SystemTo light and shut down Instant Electronic Ignition system:1.Remove access panel.

2.Turn gas shut-off valve to open position (handle should be parallel with the gas line). Refer to Figure 15.

3.Replace access panel.

4.Start tumbler in drying cycle. Spark igniter will begin high intensity sparking as the gas valve simultaneously opens. The gas burner(s) are ignited by the sparking igniter. Igniter will shut off, and burner(s) will remain on as long as the temperature control calls for heat.

5.Opening the tumbler door will cause flame to extinguish. Closing door and starting tumbler will restart ignition cycle.

IMPORTANT: The Instant Electronic Ignition system will attempt to light the gas by sparking for approximately 15 seconds. If gas ignition does not take place within 15 seconds the Instant Electronic Ignition control will go into safety lockout and the valve will no longer open until the Instant Electronic Ignition control is reset. To reset Instant Electronic Ignition control, remove power from control by opening and closing the loading door. If condition persists, check that the gas shut-off valve is in open position and that the gas service is properly connected. If condition still persists, remove tumbler from service.

6.To remove tumbler from service, disconnect electrical service, and turn gas shut-off valve to closed position (handle should be at right angle to the gas line).

3

2

4 1

 

7

 

5

 

 

6

T087K

 

 

 

 

 

 

T087K

1

Closed Position

5

Burner Support Bracket

2

Open Position

6

Spud Holder

3

Gas Shut-Off Valve

7

Union Nut

4Manometer

Figure 15

40

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

M414038