Electrical Requirements

Electrical RequirementsRefer to Table 10.

NOTE: Minimum wire sizes are obtained from Canadian Electrical Code and are intended for use as a guideline only. Electrical connections should be made only by a qualified electrical contractor in accordance with all applicable local and national requirements.

NOTE: Connect to an individual branch circuit.NOTE: Use copper conductors only.
120 Pound Tumbler Model
Serial Plate VoltageTerminal BlockRatedBreaker

Breaker

Recommended
Connections RequiredCurrent*RatingPoles

Wire Size

 

 

 

 

 

 

 

208 – 230V/60Hz/3ph

L1, L2, L3 and ground

6.7

10 Amps

3

14 AWG (2.6 mm2)

380 – 415V/50Hz/3ph

L1, L2, L3 and ground

4.7

10 Amps

3

14 AWG (2.6 mm2)

460 – 480V/60Hz/3ph

L1, L2, L3 and ground

4.0

10 Amps

3

14 AWG (2.6 mm2)

 

 

 

 

 

 

 

170 Pound Tumbler Model

 

 

 

 

 

 

 

 

Serial Plate Voltage

Terminal Block

Rated

Breaker

Breaker

Recommended

Connections Required

Current

Rating

Poles

Wire Size

 

 

 

 

 

 

 

208 – 230V/60Hz/3ph

L1, L2, L3 and ground

12.7

15 Amps

3

14 AWG (2.6 mm2)

380 – 415V/50Hz/3ph

L1, L2, L3 and ground

7.3

10 Amps

3

14 AWG (2.6 mm2)

460 – 480V/60Hz/3ph

L1, L2, L3 and ground

6.6

10 Amps

3

14 AWG (2.6 mm2)

* Current ratings vary slightly depending on model; refer to serial plate.

Table 10

48

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

M414038