Specifications and Dimensions

Direct Steam Heating (Optional)

Steam inlet connection size,

1/2 (13)

1/2 (13)

1/2 (13)

1/2 (13)

3/4 (19)

3/4 (19)

in (mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of steam inlets

 

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

LO

2.1 (1.5)

3.3 (2.4)

4.6 (3.3)

5.7 (4.1)

6.7 (4.9)

8.3 (6.0)

 

 

W

 

 

 

 

 

 

Steam required to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

raise bath

 

ME

2.3 (1.7)

3.7 (2.6)

5.2 (3.8)

6.5 (4.7)

7.8 (5.6)

9.5 (6.9)

temperature

 

D

 

 

 

 

 

 

10°F, lb (10°C, kg)

 

 

 

 

 

 

 

 

 

HIG

2.7 (1.9)

4.1 (2.9)

6.1 (4.4)

7.6 (5.5)

9.1 (6.6)

11.1 (8.0)

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Average consumption per

1.4 (21.4)

2.1 (33.4)

3.1 (48.4)

3.8 (60.4)

4.6 (72.0)

5.8 (91.0)

cycle, BHP (kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Heating (Optional)

Total electrical heating

 

15.6

25.2

37.8

37.8

50.4

N/A

capacity, kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of electrical heating

6

6

9

9

12

N/A

elements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical heating element

2.6

4.2

4.2

4.2

4.2

N/A

size, kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO

2.4 (3.6)

2.4 (3.7)

2.2 (3.4)

2.8 (4.2)

2.5 (3.8)

N/A

 

W

 

 

 

 

 

 

Time required to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

raise bath

ME

2.7 (4.1)

2.7 (4.1)

2.5 (3.9)

3.2 (4.8)

2.9 (4.4)

N/A

temperature

D

 

 

 

 

 

 

10°F, min (5°C, min)

 

 

 

 

 

 

 

HIG

3.1 (4.7)

3.0 (4.6)

3.0 (4.5)

3.7 (5.6)

3.4 (5.1)

N/A

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Refer to Figure 1, and serial number decal on machine to determine design series.

**Gap setting should be made with “GO–NO-GO” type feeler gauge.

10

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232084