Specifications and Dimensions

Steam Requirements (Steam Heat Option Only)

WARNING

Never touch internal or external steam pipes, connections, or components. These surfaces can be extremely hot and will cause severe burns. The steam must be turned off and the pipe, connections, and components allowed to cool before the pipe can be touched.

SW014

For washer-extractors equipped with optional steam heat, install piping in accordance with approved commercial steam practices. Steam requirements are shown in Table 8.

NOTE: Failure to install the supplied steam filter may void the warranty.

UWPV Pocket Hardmount

Steam Supply Information

 

35

60

80

100

125/150

 

 

 

 

 

 

Steam inlet connection, in

1/2 (DN13)

1/2 (DN13)

1/2 (DN13)

1/2 (DN13)

3/4 (DN19)

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of steam inlets

 

1

 

1

 

 

1

 

1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

Recommended pressure, psi

30

– 80

30

80

30

– 80

30

– 80

30

– 80

(bar)

(2.0

– 5.5)

(2.0

5.5)

(2.0

– 5.5)

(2.0

– 5.5)

(2.0

– 5.5)

 

 

 

 

 

 

Maximum pressure, psi (bar)

80 (5.5)

80 (5.5)

80 (5.5)

80 (5.5)

80 (5.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 8

 

 

 

 

 

 

34

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232084