Designs 1-4

1

2 3

4

5

6

P041I

P041I

1Tubing from Pump

2Seal Nut

3Tubing Ring

4Base

5Lid

6Nut

Figure 21

Specifications and Dimensions

Connecting External Liquid Supplies to the Washer-Extractor

1.Remove plugs from base. Refer to Figure 21. Plugs are assembled inside the tubing ring.

2.Install strain reliefs, included in the seal nut.

3.Insert tubes through base. Do not remove cups. Tube should extend into the plastic cup, with the exception of the softener tube, which should be routed to the outside of the cup.

4.Tighten the seal nut to prevent tubing from escaping the assembly.

5.Before operating machine, confirm lid is completely closed.

Do not attempt to make chemical injection electrical connections to points other than those provided specifically for that purpose by the factory.

Chemical Injection Supply System

Number of dry supply compartments

5

 

 

Number of liquid supply connections

5

 

 

Liquid supply connection size,

0.63 (15.9)

in (mm)

 

 

 

F232084

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

39