Chapter 2: Installation

2.Using a flat-head screwdriver, remove the snap-on plastic feet from the bottom of the switch, as shown in Figure 13.

Figure 13. Removing the Feet

3.Turn the switch over.

4.Attach a rackmounting bracket to one side of the switch using four of the screws that came with the switch. You can install the brackets in one of four ways, as shown in Figure 12.

5.Install the second rackmounting bracket on the other side of the switch using the four remaining screws.

6.Mount the switch in the 19-inch rack using standard screws (not provided).

Warning: To prevent electric shock, do not remove the cover. No user-serviceable parts inside. This unit contains hazardous voltages and should only be opened by a trained and qualified technician. To avoid the possibility of electric shock, disconnect electric power to the product before connecting or disconnecting the LAN cables.  E1

Warning: Do not work on equipment or cables during periods of lightning activity.  E2

Warning: Power cord is used as a disconnection device. To de- energize equipment, disconnect the power cord.  E3

Warning: Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.  E4

Pluggable Equipment. The socket outlet shall be installed near the equipment and shall be easily accessible.  E5