Chapter 2: Installation

Planning the Installation

Table 10 contains the cabling specifications for the twisted pair ports.

Table 10. Twisted Pair Cabling and Distances

 

 

 

Maximum

Model

Speed

Cable Type

Operating

 

 

 

Distance

 

 

 

 

 

 

 

 

AT-8524M

10 Mbps

Category 3 or better

100 m (328 ft)

AT-8524POE

 

100-ohm shielded or

 

AT-8550GB

 

unshielded twisted pair

 

AT-8550SP

 

cable

 

 

 

 

 

 

100 Mbps

Category 5 or Category

100 m (328 ft)

 

 

5E (Enhanced)

 

 

 

100-ohm shielded or

 

 

 

unshielded twisted pair

 

 

 

cable

 

 

 

 

 

AT-8550GB

1000 Mbps

Category 5 and

100 m (328 ft)

AT-8550SP

 

Category 5E

 

(Ports 49R

 

(Enhanced) 100-ohm

 

and 50R)

 

shielded or unshielded

 

 

 

twisted pair cable

 

 

 

 

 

Note

The twisted pair ports on the switch feature auto-MDI/MDI-X. They configured themselves automatically as MDI or MDI-X when connected to an end node. This allows you to use a straight-through twisted pair cable when connecting any type of network device to a port on the switch.

The auto-MDI/MDI-X feature is disabled if you disable Auto- Negotiation on a port and set a port’s speed and duplex mode manually using the AT-S62 management software. A port where Auto-Negotiation has been disabled defaults to MDI-X. Disabling Auto-Negotiation may require that you manually configure a port’s MDI/MDI-X setting or use a crossover cable.

Note

The 10/100/1000Base-T ports, Ports 49R and 50R, on the AT-8550GB and AT-8550SP switches can operate at 1000 Mbps only when set to Auto-Negotiation, which is the default setting. You cannot manually set these ports to 1000 Mbps.

52

Page 52
Image 52
Allied Telesis AT-8500 Series manual Planning the Installation, Maximum, Model Speed Cable Type