Allied Telesis GS900/5E manual Planning the Installation, Speed, Type of Cable, Maximum

Models: GS900/5E

1 40
Download 40 pages 33.63 Kb
Page 25
Image 25
Planning the Installation

AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide

Planning the Installation

Table 3 contains the cabling specifications for the twisted pair ports.

Table 3. Twisted Pair Cabling and Distances

Speed

Type of Cable

Maximum

Operating

 

 

Distance

 

 

 

10 Mbps

Category 3 or better 100-ohm

100 m (328 ft)

 

shielded or unshielded twisted pair

 

 

cable

 

 

 

 

100 Mbps

Category 5 or Category 5E

100 m (328 ft)

 

(Enhanced) 100-ohm shielded or

 

 

unshielded twisted pair cable

 

 

 

 

1000 Mbps

Category 5 and Category 5E

100 m (328 ft)

 

(Enhanced) 100-ohm shielded or

 

 

unshielded twisted pair cable

 

 

 

 

Note

The twisted pair ports on the switch feature Auto-MDI when operating at either 10, 100, or 1000 Mbps. Each port is individually configured as MDI or MDI-X when connected to an end-node. Consequently, you can use either a straight-through or crossover twisted pair cable when connecting any network device to a twisted pair port on the switch. For example, a port operating at 10 or 100 Mbps uses two pairs of twisted pair wiring while a port operating at 1000 Mbps uses four pairs of twisted pair wiring.

25

Page 25
Image 25
Allied Telesis GS900/5E manual Planning the Installation, Speed, Type of Cable, Maximum