Allied Telesis X900-48FE-N manual Configure the transit node switch B that belongs just to domain

Models: AT-9924SP-30 AT-9924T-40 AT-8948 AT-9924T/4SP-A-20 X900-48FE-N

1 56
Download 56 pages 22.23 Kb
Page 15
Image 15
2.Configure the transit node (switch B) that belongs just to domain 1

Example 2: A Double Ring

2.Configure the transit node (switch B) that belongs just to domain 1

This transit node is the same as in the previous example (except that the domain has been renamed).

create vlan=vlan1000 vid=1000

add vlan=1000 port=1-2 frame=tagged create vlan=vlan2 vid=2

add vlan=2 port=1-2 frame=tagged delete vlan=1 port=1-2

create epsr=domain1 mode=transit controlvlan=vlan1000 add epsr=domain1 datavlan=vlan2

enable epsr=domain1

3.Configure the master node (switch C) for domain 2

Configure the control VLAN: create vlan=vlan40 vid=40

add vlan=40 port=4-5 frame=tagged

Configure the data VLAN: create vlan=vlan50 vid=50

add vlan=50 port=4-5 frame=tagged

Remove the ring ports from the default VLAN:

delete vlan=1 port=4-5

Configure EPSR:

create epsr=domain2 mode=master controlvlan=vlan40 primaryport=4 add epsr=domain2 datavlan=vlan50

enable epsr=domain2

4.Configure the transit node (switch D) that belongs just to domain 2

Configure the control VLAN: create vlan=vlan40 vid=40

add vlan=40 port=4-5 frame=tagged Configure the data VLAN:

create vlan=vlan50 vid=50

add vlan=50 port=4-5 frame=tagged

Remove the ring ports from the default VLAN:

delete vlan=1 port=4-5

Page 15 AlliedWare™ OS How To Note: EPSR

Page 15
Image 15