Allied Telesis AT-9924T/4SP-A-20, AT-8948 The master node transmits and receives Health messages

Models: AT-9924SP-30 AT-9924T-40 AT-8948 AT-9924T/4SP-A-20 X900-48FE-N

1 56
Download 56 pages 22.23 Kb
Page 41
Image 41
12.The master node transmits and receives Health messages

Debugging

12.The master node transmits and receives Health messages

The master node continues transmitting and receiving Health messages for as long as the ring stays in a state of Complete.

Manager x900-48-A>

epsrHelloTimeout: EPSR test Hello Timer expired

EPSR Port1 Tx: 00e02b00 00040000 cd280619 8100e3e8 005caaaa 0300e02b 00bb0100 00541eed 00000000 0000cd28 0619990b 00400105 03e80000 00000000 cd280619 00010002 010000fb

EPSR Port1 Tx:

-----------------------------------------------------------------------

TYPE

= HEALTH

STATE

= COMPLETE

CTRL VLAN

= 1000

SYSTEM

=

00-00-cd-28-06-19

HELLO TIME

=

1

FAIL TIME

=

2

HELLO SEQ

=

251

 

 

 

-----------------------------------------------------------------------

EPSR Port2 Rx: 00e02b00 00040000 cd280619 8100e3e8 005caaaa 0300e02b

00bb0100 00541eed

00000000

0000cd28

0619990b

00400105

03e80000

00000000 cd280619

00010002

010000fb

 

 

 

EPSR Port2 Rx:

-----------------------------------------------------------------------

TYPE

= HEALTH

STATE

= COMPLETE

CTRL VLAN

= 1000

SYSTEM

=

00-00-cd-28-06-19

HELLO TIME

=

1

FAIL TIME

=

2

HELLO SEQ

=

251

 

 

 

-----------------------------------------------------------------------

.

.

.

Page 41 AlliedWare™ OS How To Note: EPSR

Page 41
Image 41
Allied Telesis AT-9924T/4SP-A-20, X900-48FE-N, AT-8948 The master node transmits and receives Health messages, Debugging