Debugging
2.The link between the two transit nodes goes down
When the link goes down, the master node transmits a Health message but does not receive it on its secondary port.
Manager
epsrHelloTimeout: EPSR test Hello Timer expired
EPSR Port1 Tx: 00e02b00 00040000 cd280619 8100e3e8 005caaaa 0300e02b 00bb0100 00541ea0 00000000 0000cd28 0619990b 00400105 03e80000 00000000 cd280619 00010002 01000148
EPSR Port1 Tx:
TYPE | = HEALTH | STATE | = COMPLETE | ||
CTRL VLAN | = 1000 | SYSTEM | = | ||
HELLO TIME | = | 1 | FAIL TIME | = | 2 |
HELLO SEQ | = | 328 |
|
|
|
3.The master node receives a Link-Down message on its secondary port
The master node receives a
EPSR Port2 Rx: 00e02b00 00040000 cd20f101 8100e3e8 005caaaa 0300e02b 00bb0100 00544726 00000000 0000cd20 f101990b 00400108 03e80000 00000000 cd20f101 00000000 04000000
EPSR Port2 Rx:
TYPE | = | STATE | = | ||
CTRL VLAN | = 1000 | SYSTEM | = | ||
HELLO TIME | = | 0 | FAIL TIME | = | 0 |
HELLO SEQ | = | 0 |
|
|
|