C: INSTALLING THE OPERATOR

TERMINAL STRIP REFERENCE CHART

#NAME

1LOCK SOLENOID

2LOCK SOLENOID

3COMMON

4CLOSE LIMIT SWITCH

5OPEN LIMIT SWITCH

6STOP

7CLOSE

8RADIO OPEN

9REVERSING

10 HOLD OPEN

DESCRIPTION

One of (2) board commons provided on the terminal strip

Used to configure right hand/left hand operation — See P. 13, Fig 11, Limit Switch Wires.

NOTE: Ensurethatwiretoterminal4 issamecoloraswire to terminal14.

Used to configure right hand/left hand operation — See P. 13, Fig 11, Limit Switch Wires.

NOTE: Ensurethatwiretoterminal5 issamecoloraswire to terminal15.

Continuous or pulsed signal. Overrides all other signals. Once activated, the gate will immediately stop and await a new command. If the STOP input is continuously activated, the gate will not move.

Pulsed signal. CLOSE overrides all other signals except HOLD OPEN, STOP, and REVERSING. Once activated, the gate will close immediately.

Pulsed signal. Once activated the gate will open fully. Activation while the gate is closing will cause it to re-open.

This input is active only when the gate is closing or when it’s fully open and the Close Timer is operative. All stand-alone vehicle detectors, photo-eyes and active edges should be connected here and to terminals #3 or #13 COMMON. Multiple devices may be connected in parallel.

Continuous or pulsed signal. Usually used with an external toggle switch or free exit vehicle detector. Once activated, the gate will open fully and remain open until the HOLD OPEN signal is no longer present. If the close time is enabled, the controller will time- out and close the gate once the HOLD OPEN input is no longer active

11

PULSE OPEN

Pulsed signal. Identical in

 

 

operation to RADIO OPEN input.

 

 

Used for access control devices

 

 

such as telephone entry, keypads,

 

 

card readers and 3-button

 

 

stations.

12

ALTERNATE

Pulsed signal. This input is used

 

 

for “COMMAND OPEN/

 

 

COMMAND CLOSE” applications.

 

 

The 1st signal will cause the gate

 

 

to begin opening. A 2nd signal

 

 

received during the open cycle will

 

 

stop the gate immediately. A 3rd

 

 

signal will close the gate. Connect

 

 

appropriate access control device

 

 

to this terminal and #3 or #13

 

 

COMMON. Disable the Close

 

 

Timer.

13

COMMON

Second of (2) board commons

 

 

provided on the terminal strip.

14

MOTOR RUN

Used to configure right hand/left

 

WINDING

hand operation — See Section C.

 

 

Figs. 11 & 12, Motor Control

 

 

Wires.

 

 

NOTE: Ensurethatwiretoterminal14

 

 

issamecoloraswire to terminal4.

15

MOTOR RUN

Used to configure right hand/left

 

WINDING

hand operation — See Section C,

 

 

Figs. 11 & 12. Motor Control

 

 

Wires

 

 

NOTE: Ensurethatwiretoterminal15

 

 

issamecoloraswire to terminal5

16

MOTOR COMMON

Center tap for motor run windings

17

AC INPUT

 

18

AC INPUT

 

 

 

 

18

Page 18
Image 18
Allstar Products Group HDSWG 1000 owner manual # Name, Description