SE RVIC E
This section is provided for the assistance of qualified technicians only and is not intended for use by untrained or unau thorized service personnel . If your
Check the power flow to the unit. Plug in outlet? Circuit breaker switch at back of unit turned on?
☛ Do not attempt to repair or service the Cook and Hold unit beyond this point. Contact
TROU BLE SHOO TING | IN TERNAL | ELEC TRICAL | COMPON ENT S | ||
|
|
|
|
| |
A. No power . | Display will | not ligh t. |
|
| |
1. | Verify that | power is available at the out let or junct ion box. |
| ||
2. | Verify that | the circuit breaker swi tch on the back of the unit is turn ed on. |
| ||
3. | Verify that the power cord is not open. Che ck continu ity with a VOM met er. | ||||
4. | If none of the abov e steps help, cal l a qualified | service tech nician or refer | to the Service Manu al for | ||
| this particular ove n. |
|
|
|
B. Display is lit and unit calls for hea t, but unit is not heating;
Error Code E30
Check to verify that the high limit switch located at the rear of the unit top has not been tri pped. If it has been tri pped, reset by pressin g in the hit limit reset butto n at the rear of the ove n.
Afte r reset ting, the caus e of the high limit trip must be corr ect ed. If the high limit switch will not rese t, the hig h lim it switch is def ect ive and must be replaced . This is a safe ty dev ice and mus t not be jumpe d out or removed from the circui t.
C.ToTest testair senairsor bysenplacsoring:sensor in ice wate r bath and using an ohmmeter set on the ohm scale. The read ing shou ld be 100 ohms resistance . If it is more than 2 ohm s higher or lower, sensor needs to be replace d.
D.TestTo testfood probeprobeby placsensoring in :ice water bath and using an ohmmeter set on the ohm scale. The reading shoul d be 100 ohm s resistance.
DA NGE R
DIS CONNECT UNI T FROM
POWER SOURCE BEF ORE
CLEANI NG OR SER VICING .
C A U TI ON
THIS SECTION IS PROVIDED FORTHE ASSISTANCE OF QUALIFIED SERVICETECHNICIANS ONLYAND IS NOT INTENDED FOR USE BY UNTRAINED OR UNAUTHORIZED SERVICE PERSONNEL.
N OTE
If the appliance has bee n unplugged for an extended period of time, the Real Time Clock may require recha rging. Plug the unit into the proper recept acle for a minim um of 24 hour s.
767- SK/III, 1767 | PG . 23 |