SE RVIC E

This section is provided for the assistance of qualified technicians only and is not intended for use by untrained or unau thorized service personnel . If your Alto-Shaam® unit is not operating properly, check the followin g before calling your Authorized Alto- Shaam® Service Agent:

Check the power flow to the unit. Plug in outlet? Circuit breaker switch at back of unit turned on?

Do not attempt to repair or service the Cook and Hold unit beyond this point. Contact Alto-Shaam®for the nearest authorized service agent. Repairs made by any other service agents without prior authorization by Alto-Shaam®will void the warranty on the unit.

TROU BLE SHOO TING

IN TERNAL

ELEC TRICAL

COMPON ENT S

 

 

 

 

 

A. No power .
Display will
not ligh t.

 

 

1.

Verify that

power is available at the out let or junct ion box.

 

2.

Verify that

the circuit breaker swi tch on the back of the unit is turn ed on.

 

3.

Verify that the power cord is not open. Che ck continu ity with a VOM met er.

4.

If none of the abov e steps help, cal l a qualified

service tech nician or refer

to the Service Manu al for

 

this particular ove n.

 

 

 

B. Display is lit and unit calls for hea t, but unit is not heating;
Error Code E30

Check to verify that the high limit switch located at the rear of the unit top has not been tri pped. If it has been tri pped, reset by pressin g in the hit limit reset butto n at the rear of the ove n.

Afte r reset ting, the caus e of the high limit trip must be corr ect ed. If the high limit switch will not rese t, the hig h lim it switch is def ect ive and must be replaced . This is a safe ty dev ice and mus t not be jumpe d out or removed from the circui t.

C.ToTest testair senairsor bysenplacsoring:sensor in ice wate r bath and using an ohmmeter set on the ohm scale. The read ing shou ld be 100 ohms resistance . If it is more than 2 ohm s higher or lower, sensor needs to be replace d.

D.TestTo testfood probeprobeby placsensoring in :ice water bath and using an ohmmeter set on the ohm scale. The reading shoul d be 100 ohm s resistance.

TROU BLE SHOO TING DA NGE R

DIS CONNECT UNI T FROM

POWER SOURCE BEF ORE

CLEANI NG OR SER VICING .

C A U TI ON

THIS SECTION IS PROVIDED FORTHE ASSISTANCE OF QUALIFIED SERVICETECHNICIANS ONLYAND IS NOT INTENDED FOR USE BY UNTRAINED OR UNAUTHORIZED SERVICE PERSONNEL.

N OTE

If the appliance has bee n unplugged for an extended period of time, the Real Time Clock may require recha rging. Plug the unit into the proper recept acle for a minim um of 24 hour s.