INSTALLATION REQUIREMENTS
The oven must be mounted on the factory equipped oven legs or on an optional oven stand. Installation on a solid or concrete base that in any way restricts air flow may void the warranty.
All clearances for a proper ventilation air supply must be maintained to minimize fire hazard. Do not locate the oven immediately adjacent to any other
I N S T A L L A T I O N
C A U T I O N
TO PREVENT PERSONAL INJURY, USE CAUTION WHEN MOVING OR LEVELING THIS APPLIANCE.
D A N G E R
IMPROPER INSTALLATION,ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULDRESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.READ THE INSTALLATION,
OPERATING AND MAINTENANCEINSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICINGTHIS EQUIPMENT.
A number of adjustments are associated with initial installation and
LEVELING
The oven should be leveled
the gas supply is connected. Level the oven from
We recommend checking the level of the oven periodically to make certain the floor has not shifted nor the oven moved.
RESTRAINT REQUIREMENTS —MOBILE EQUIPMENT
WARNING
RISK OF ELECTRIC SHOCK.
Appliance must be securedto building structure.
Any appliance that is not furnished with a power supply cord but includes a set of casters must be provided with a tether. Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit. The following requirements apply:
1.Casters must be a maximum height of 6" (152mm).
2.Two of the casters must of be the locking type.
3.Such mobile appliances or appliances on mobile stands must be installed with the use of a flexible connector secured to the building structure.
A mounting connector for a restraining device
is located on the lower back flange of the appliance chassis or on an oven stand, approximately
18" (457mm) from the floor. A flexible connector is not supplied or available from the factory.
Where automatically operated appliances are vented through a ventilating hood or exhaust system equipped with a damper or with a power means of exhaust, provisions shall be made to allow the equipment to operate only when the damper is open to a position to properly vent the appliance and when the power means of exhaust is in
operation. A C C O R D A N C E W I T H NFPA 54 C O M M O N W E A L T H O F M A S S A C H U S E T T S O N L Y .