LEVELING

INST A L L A TIO N

S IT E INSTALLATION

A number of adjustments are associated with initial installation and start-up. It is important that these adjustments be conducted by a qualified service technician. Installation and start-up adjustments are the responsibility of the dealer or user. These adjustments include but are not limited to thermostat calibration, door adjustment, leveling, electrical hook-up and installation of optional casters or legs.

LEVELING

Level the oven from side-to-side and front-to-back with the use of a spirit level. For ovens installed with casters, it is important that the installation surface be level due to the probability of frequent oven repositioning.

We recommend checking the level of the oven periodically to make certain the floor has not shifted nor the oven moved.

NOTE: Failure to properly level this oven may result spills from a semi-liquid product.

RESTRAINT REQUIREMENTS —MOBILE EQUIPMENT

RESTRAINT REQUIREMENTS —MOBILE EQUIPMENT warnIng

rISK oF eleCtrIC SHoCK.

Appliance must be secured

to building structure.

Any appliance that is not furnished with a power supply cord but that includes a set of casters must be installed with a tether. Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit. The following requirements apply:

1.Maximum height of casters is 6" (152mm).

2.Two of the casters must of be the locking type.

3.Such mobile appliances or appliances on mobile stands must be installed with the use of a flexible connector secured to the building structure.

A mounting connector for a restraining device is located on the upper back flange of the appliance. A flexible connector is not supplied by nor is it available from the factory.

holding cabinets installation/operation/service manual - pg. 11

Page 13
Image 13
Alto-Shaam 1000-UP, 300-S Leveling, Restraint Requirements -Mobile Equipment, rISK oF eleCtrIC SHoCK, Inst A L L A Tio N