Alto-Shaam Holding Cabinet Danger, Inst A L L A Tio N, E L Ect Ri Ca L, On Appliance Rating Tag

Models: 1200-S 1000-S 1000-UP 750-S 1200-UP 500-S 300-S Holding Cabinet

1 51
Download 51 pages 31 b
Page 16
Image 16
Manual background

INST A L L A TIO N

E L ECT RI CA L

300-S

voltage phase cycle/hz amps kW cord & plug

120

1

60

6.7

.80

nema 5-20p

 

 

 

 

 

20A-125v plug

 

230

1

50/60

3.9

.80

cee 7/7

 

 

 

 

 

 

220-230v plug

 

 

 

 

 

 

 

 

500-S

 

 

 

 

 

 

voltage

phase cycle/hz

amps

kW

cord & plug

 

120

1

60

8.4

1.0

nema 5-15p,

 

 

 

 

 

 

15A-125v plug

 

208

1

60

3.7

.76

nema 6-15p,

 

240

1

60

4.2

1.0

15A-250v plug

 

 

 

 

 

 

(USA ONLY)

 

230

1

50/60

4.1

.95

cee 7/7,

 

 

 

 

 

 

220-230v plug

 

 

 

 

 

 

 

 

750-S

 

 

 

 

 

 

voltage

phase cycle/hz

amps

kW

cord & plug

 

120

1

60

9.0

1.1

nema 5-15p,

 

 

 

 

 

 

15A-125v plug

 

208

1

60

3.9

.81

nema 6-15p,

 

240

1

60

4.5

1.1

15A-250v plug

 

 

 

 

 

 

(USA ONLY)

 

230

1

50/60

4.3

1.0

cee 7/7,

 

 

 

 

 

 

220-230v plug

 

 

 

 

 

 

 

 

1000-S

 

 

 

 

 

 

voltage

phase cycle/hz

amps

kW

cord & plug

 

120

1

60

8.0

.96

nema 5-15p,

 

 

 

 

 

 

15A-125v plug

 

208

1

60

3.5

.72

nema 6-15p,

 

240

1

60

4.0

.96

15A-250v plug

 

 

 

 

 

 

(USA ONLY)

 

230

1

50/60

3.9

.88

cee 7/7,

 

 

 

 

 

 

220-230v plug

1200-S

 

 

voltage

phase cycle/hz

amps kW

cord & plug

120

120

1

60

 

8.0

.96

nema 5-15p,

 

 

 

 

 

 

 

15A-125v plug

 

 

 

 

 

 

 

 

 

240

1000W

208

1

60

 

3.5

.72

nema 6-15p,

240

1

60

 

4.0

.96

15A-250v plug

 

 

 

-

 

 

 

 

 

 

 

 

(usa only)

 

208

1

60

 

6.9

1.4

 

208

2000W

 

no cord

240

1

60

 

8.0

1.9

or plug

 

 

 

 

 

 

 

 

 

 

 

 

230

230

1000W

1

50/60

3.9

.88

cee 7/7,

230 2000W

1

50/60

7.7

1.8

220-230v plug

 

 

 

 

 

 

 

 

 

 

 

 

1000-UP

 

 

 

 

 

 

 

 

 

voltage

phase

cycle/hz

amps

kW

cord & plug

 

 

120

 

1

60

16.0

1.9

nema 5-20p,

 

 

 

 

 

 

 

 

 

20A-125v plug

 

 

208

 

1

60

7.0

1.4

nema 6-15p,

 

 

240

 

1

60

8.0

1.9

15A-250v plug

 

 

 

 

 

 

 

 

 

(usa only)

 

 

 

 

 

 

 

 

 

 

 

230

 

1

50/60

7.7

1.8

cee 7/7,

 

 

 

 

 

 

 

 

 

220-230v plug

1200-UP

voltage phase cycle/hz amps kW cord & plug

120

120

1

60

16.0

1.9

nema 5-20p,

 

 

 

 

 

20A-125v plug

 

 

 

 

 

 

240 2000W

208

1

60

7.0

1.4

nema 6-15p,

240

1

60

8.0

1.9

(usa only)

 

15A-250v plug

-

208

1

60

14.0

2.9

 

208 4000W

no cord

240

1

60

16.0

3.8

or plug

 

 

 

 

 

 

 

 

230

230 2000W

1

50/60

7.7

1.8

cee 7/7,

230 4000W

1

50/60

15.4

3.5

220-230v plug

Wire diagrams are located inside the bonnet of the unit..

CaUtIon

THIs sECTION Is PROVIDED FOR THE AssIsTANCE OF QUALIFIED sERVICE TECHNICIANs ONLY AND Is NOT INTENDED FOR UsE BY UNTRAINED OR UNAUTHORIZED sERVICE PERsONNEL.

Manual background Danger

ENsURE POWER sOURCE

MATCHEs VOLTAGE IDENTIFIED

ON APPLIANCE RATING TAG.

holding cabinets installation/operation/service manual - pg. 14

Page 16
Image 16
Alto-Shaam Holding Cabinet Danger, Inst A L L A Tio N, E L Ect Ri Ca L, ENsURE POWER sOURCE MATCHEs VOLTAGE IDENTIFIED