To Convert from Natural Gas to L.P. Gas

NOTE: ALL dryers are sold as natural gas, unless otherwise specified at the time the dryer order was placed. For L.P. gas the dryer must be converted as follows.

1.Refer to "Replace Gas Valve" and follow steps 1 through 6. a. For models with 1" Robertshaw valve.

2.Remove the four (4) screw which secure the top cap assembly. This assembly contains the regulator adjustment screw and the terminal connections.

3.Replace the top cap assembly with the L.P. version.

4.Unscrew main burner orifices and replace with L.P. orifices.

NOTE: Use extreme care when removing and replacing orifices. These orifices are made of brass and are easily damaged.

5. Reverse the procedure for reinstalling valve assembly to the dryer.

WARNING: Test ALL connections for leaks by brushing on a soapy water solution.

NEVER TEST FOR LEAKS WITH A FLAME.

NOTE: There is no regulator provided in an L.P. dryer. at the source (L.P. tank) or an external regulator

The column pressure must be regulated must be added to each dryer.

19

Page 23
Image 23
American Dryer Corp AD-170 service manual To Convert from Natural Gas to L.P. Gas