To Test and Adjust Gas (Water Column) Pressure
There are two (2) types of devices commonly used to measure water column pressure. They are spring/mechanical- type gauges and manometers. The
NOTE: Manometers are available from the factory by ordering ADC P/N 122804
1. To Test Gas Water Column (W.C.) Pressure:
a. Connect water column test gauge connection to gas valve pressure tap (1/8" NPT). This pressure tap is located on the outlet (manifold) side of the valve.
b. Start dryer. With burner on, the correct water column reading in inches would be:
Natural Gas – 3.5 to 4 Inches Water Column
L.P. Gas – 10.5 to 11 Inches Water Column
2.To Adjust Water Column Pressure (natural gas only, L.P. gas must be regulated at source):
a. Remove the slotted vent cap on the top of the valve.
b. Turn the slotted adjustment screw located on the top of the valve next to the terminals. Turn clockwise to increase manifold pressure and counterclockwise to decrease.
NOTE: If correct W.C. pressure cannot be achieved, problem may be due to an undersized gas supply line, a faulty or underrated gas meter, etc.