6 MONTHS

Inspect and remove lint accumulation in customer-furnished exhaust

 

duct work system. Inspect exhaust back draft dampers to insure they

 

are not binding. Inspect and remove ALL lint accumulation from in

 

and around control box area, including coin acceptors. Clean lint

 

accumulation from around tumbler wrapper area.

WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK CAN CREATE A POTENTIAL FIRE HAZARD.

AS REQUIRED

In cleaning and care of the cabinet, avoid using harsh abrasives. A

 

product intended for the cleaning of appliances is recommended.

B. Adjustments

SUGGESTED INTERVAL

FUNCTION

6 MONTHS

Motor and drive beltsshould be examined. Cracked or seriously frayed

 

belts should be replaced. Tighten loose belts when necessary, and

 

check belt alignment.

6 MONTHS

Complete operational check of controls and valves.

6 MONTHS

Complete operational check of ALL safety devices (door switches,

 

sail switch, burner and lint chamber thermostats.)

12 MONTHS

Inspect bolts, nuts, screws, non-permanent gas connections, (unions,

 

orifices, etc.) electrical terminals, and grounding connections.

C. Lubrication

Lubrication is necessary on the fan bearings (2) 50 & 60Hz steam models, and 50Hz gas models ONLY. This should be performed every 90 days.