C. No Heat Condition (Gas)

1.Check to see if D.S.I. module fault indicator L.E.D. is red. If red, refer to ADC D.S.I. troubleshooting manual (P/N 450142).

2.Check for voltage across the "TH" and "GND" terminal of the module. If voltage is evident refer to ADC D.S.I. technical manual (P/N 450142).

NOTE: In the preceding steps, when checking the voltage leave one of your meter lead

to terminal block #7 or any good ground connection. Make sure sail switch damper is closing properly.

IMPORTANT: By no means should the sail switch be tampered with or bypassed when under normal drying conditions.

3.Check for voltage across both terminals of the sail switch. If voltage is evident on both terminals, check for bad wire or termination on the red wire that leaves the sail switch and passes through the gas valve train connector to the "TH" terminal on D.S.I. module. If voltage is evident on one terminal of the sail switch, replace the sail switch.

4.Check for voltage across both terminal of the burner hi-limit switch.

If voltage is evident on both terminals, check for bad wire or termination on the red wire from the burner hi-limit switch through the J19 connector (top tumbler) or the J20 (bottom tumbler) connector, to the sail switch.

If voltage is evident on one terminal of the burner hi-limit switch, replace this hi-limit switch.

5.Check for voltage across both terminals of the tumbler hi-limit switch. If voltage is evident on both terminals, check for bad wire or termination on the red wire from the tumbler hi-limit switch through the J19 connector (top tumbler) or the J20 (bottom tumbler) connector, to the burner hi-limit switch. If voltage is evident on one terminal replace the tumbler hi-limit switch.

36

Page 40
Image 40
American Dryer Corp ADG-60 service manual No Heat Condition Gas