IMPORTANT: Do be sure wires removed in step 4 are connected to the correct terminal positions. When connecting the orange high voltage (HV) lead to the DSI module, be sure it is securely in place.

6.Reinstall the gas valve train, the control and lint door and the lint drawer.

7.Reestablish power to the dryer.

AA. To Replace Ignitor and Probe

1.Discontinue power to the dryer.

2.Remove the lint drawer, the control and lint door and the gas valve train assembly from dryer. Follow gas valve train removal procedures in section C.

3.To replace either ignitor probe or flame sensor simply remove phillips head screw holding device to bracket and disconnect wire.

4.Reverse steps 2 and 3 for installing the new ignitor or flame probe assembly.

5.Reestablish power to the dryer.

BB. To Replace Gas Valve

1.Discontinue power to the dryer.

2.Close all gas shut-off valves in gas supply line to the dryer.

3.Remove the lint drawer, the control and lint door, and the gas valve train assembly from dryer. Follow Gas valve removal procedure in section C.

A.Remove the two (2) sheet metal screws from bottom side of the gas valve train slide which secure the brackets at the inlet side of the gas valve.

B.Remove the two (2) sets of nuts securing the manifold bracket to the gas valve train slide and disassemble valve and manifold assembly from slide.

4.Remove 1/2" street elbow from inlet side of the gas valve.

5.Remove manifold from gas valve.

6.Remove pressure test line (brass) elbow from the gas valve pressure tap.

7.Reverse steps 4 through 6 for installing the new gas valve.

IMPORTANT: When using pipe dope for gas connections, only use pipe dope suitable for both natural gas and L.P. gas applications.

NOTE: The new gas valve is supplied with a plug at the pressure tap. Remove this plug and replace it with the brass elbow removed in step 6.

8.Reassemble the gas valve and manifold assembly to the gas valve train slide by reversing step 3.

9.Reinstall the gas valve train assembly into the dryer removed in step 3.

NOTE: Be sure the union shut-off valve at the inlet area of the gas valve is in the "on" (open) position.

10.Reinstall the control and lint door, and the lint drawer removed in step 3.

11.Open all shut-off valves closed in step 2.

12.Reestablish power to the dryer.

CC. To Convert Dryer from Natural Gas to Liquid Propane (L.P.) Gas

1.Discontinue power to the dryer.

2.Close all gas shut-off valves in the gas supply line to the dryer.