Remove any lint accumulation from coin acceptor, including the optical switch.

Inspect and remove lint accumulation in customer-furnished exhaust duct work system and from the dryer's internal exhaust ducting.

WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK CAN CREATE A POTENTIAL FIRE HAZARD.

6 MONTHS

In the cleaning of the dryer cabinet, avoid using harsh abrasives.Aproduct for the cleaning of appliances is recommended.

B.Adjustments

Seven (7) DaysAfter Installation and Every 6 Months Thereafter

Inspect bolts, nuts, screws (bearing set screws), nonpermanent gas connections (unions, shut-off valves, orifices, etc..), electrical terminations, and grounding connections.

The 12-Rib 95" (J) poly belt arrangement should be examined. A cracked or seriously frayed belt should be replaced. Tighten loose belts when necessary and check the alignment.

Complete operational check of controls and valves.

Complete operational check of all safety devices (door switches, lint compartment switches, sail switches, burner and hi-limit thermostats.

C.Lubrication

The motor bearings, idler bearings and tumbler bearings are permanently lubricated. No lubrication is necessary.

4

Page 8
Image 8
American Dryer Corp ADG-60 service manual Adjustments, Lubrication