PARAMETER NAME/ | DESCRIPTION | DISPLAY SCREENS / | |
[MENU LOCATION] |
| DEFAULT SETTINGS | |
|
|
| |
|
|
|
|
PIN Entry | Screen for entry of the active password | PIN | m+ |
Security Level {0} | (PIN). Before any changes can be |
| 0000 |
[PIN] | made, the correct pin for the desires |
|
|
| security level must be entered. Level 0 – |
|
|
| full read access. Level 1 |
|
|
| limited write access. Level 2 – full read |
|
|
| and write access. |
|
|
Rectifier Communications Fail | The maximum rectifier communications | RectFailComm | m+ |
Timeout | response time allowed before a | 1 min | |
Security Level {1} | communications failure is declared. |
|
|
[MODULES/RECT/PARAM] |
|
|
|
Rectifier Configuration Alarm | The output relay energized if the rectifier | Rect Cfg Alm | m+ |
Security Level {1} | configuration differs from its stored | Minor | |
configuration. This occurs if a rectifier is |
|
| |
| added after configuration. |
|
|
Rectifier Current Limit Alarm | The output relay that is energized or | Rect CL Alm | m+ |
Security Level {1} | special rectifier alarm group n of N that | n of N | |
| occurs when a rectifier has been forced |
|
|
| into the current limited mode. |
|
|
Rectifier Current Limit Alarm | The status will be “ON” if the rectifier has | Rect 1 CL | # |
Status | been forced into its current limited mode. | OFF | |
{Status Only} | NOTE: This information can be |
|
|
[MODULES/RECT/INFO] | viewed for each rectifier installed by |
|
|
| using the horizontal arrow keys. |
|
|
Rectifier Current Output Status | A display of the DC output current for the | Rect 1 Curr | # |
{Status Only} | individual rectifier. NOTE: This | 24.9 A | |
[MODULES/RECT/INFO] | information can be viewed for each |
|
|
| rectifier installed by using the |
|
|
| horizontal arrow keys. |
|
|
Rectifier Description | Displays the model number of the | Rect 1 Desc | # |
{Status Only} | installed rectifier. NOTE: This | MRF28H54 |
|
[MODULES/RECT/INFO] | information can be viewed for each |
|
|
| rectifier installed by using the |
|
|
| horizontal arrow keys. |
|
|
Rectifier Fail | The output relay energized if Rectifier | Rect 1ofN Almm+ | |
Security Level {1} | Fail | Minor | |
special rectifier alarm group that signifies |
|
| |
| that one rectifier has at least one alarm |
|
|
| condition. |
|
|
Rectifier Fail | The output relay energized if Rectifier | Rect 2ofN Almm+ | |
Security Level {1} | Fail | Major | |
rectifier alarm group that signifies that |
|
| |
| more than one rectifier has at least one |
|
|
| alarm condition. |
|
|
Rectifier Fail Safe Voltage | Rectifier default output voltage if | Rect Fail Safem+ | |
Security Level {1} | communication with the control unit fails. |
| |
[MODULES/RECT/PARAM] |
|
|
|
Rectifier Fan Fail Alarm | The output relay that is energized or | Rect FF Alm | m+ |
Security Level {1} | special rectifier alarm group n of N that | n of N | |
occurs when a rectifier fan has failed. |
|
| |
Page 34 | MX28B200/400 |