15HOWTO SET DETECTION RANGE (If Required) ; Fig. 18 & 19

Note: The detection distance is preset and is ideal for most installations. Should an adjustment be required follow the steps below.

1.Remove FRONT PANEL (1). See Step 9 for removing front panel instructions.

2.Remove the four COVER SCREWS (2) and COVER

(3) from ELECTRICAL BOX (4). Fig. 18.

3.Disconnect GREY SENSOR WIRE (5) from CIRCUIT BOARD. (6).

4.Keeping hands away from the front of the sensor, reconnect the GREY SENSOR WIRE (5) and quickly hang the FRONT PANEL (1) onto the ELECTRICAL BOX (4). Do not secure the FRONT PANEL (1) at this time. Note:You have 5 seconds after connecting cable to begin program process.

5.While the SENSOR CONTROL LED (6) is blinking slowly, place your hand 1 to 2 in. (30-50mm.) in front of the sensor. Fig. 19.

6.When the LED (6) stops blinking and stays "ON", move your hand to the desired position from sensor (detection zone, 15-3/4" to 31-1/2", 400 to 800mm ) and hold in place until the LED (6) begins to blink again. Fig. 19a.

Note: Maximum Detection Zone is 15-3/4" to 31-1/2", (400 to 800mm ) from sensor.

7.Once the SENSOR CONTROL LED (6) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set.

8.Replace COVER (3). Tighten COVER SCREWS (2) firmly.

Fig. 18

 

5

 

T O P

2

6

 

4

 

3

1

5

9.Replace the FRONT PANEL (1). See Step 9 for instructions on installing front panel.

10.Actuate the FLUSH VALVE:

A)Cover sensor with hand for 10 seconds. NOTE:

Stand outside of sensor detection aera.

B)Remove hand from in front of the sensor, unit will

flush in approximately 3 seconds.

Fig. 19

Fig. 19a

 

 

6 BLINKING LED

BLINKING LED

 

 

MAXIMUM

 

1" - 2" (30mm - 50mm)

DETECTION ZONE

400mm TO 800mm

 

 

(15-3/4" TO 31-1/2")

11

M968550 REV. 1.5

 

Page 12
Image 12